mabe ASCHAM09EYT Instructivo página 71

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

70
Problem
Immediately turn off and
unplug system from power
supply in the following
conditions:
error codes shown in the display
In case of error, the display of the indoor unit shows the following
codes:
Display
specifications of your air conditioner
Model
Power supply tension or Rated
tension (Volt)
Operation frequency or Rated
frequency (hertz)
Rated power (Watt) or Rated
current (Amper)
Capacity (BTU/h)
Model
Power supply tension or Rated
tension (Volt)
Operation frequency or Rated
frequency (hertz)
Rated power (Watt) or Rated
current (Amper)
Capacity (BTU/h)
Possible Cause
• Abnormal and strong noise during opera-
tion.
• Faulty electronic control board.
• Faulty fuses or thermic switches.
• Water was accidentally sprayed on the
appliance or there are foreign objects in-
side the appliance.
• Overheated cables or plugs.
• Strong odor coming out from the appli-
ance.
LED
Description of error
Fault of indoor temperature sen-
Flashes once
sor.
Fault of indoor pipe temperature
Flashes twice
sensor.
Flashes 6 times
Malfunction of indoor fan motor.
AS
CHAM09EYT ASCHAM12EYT
220 V ~
220 V ~
50 Hz
50 Hz
970 W
1 280 W
9 000 BTU/h
12 000 BTU/h
ASCHAM18EYT ASCHAM24EYT
220 V ~
220 V ~
50 Hz
50 Hz
1 991 W
2 654 W
18 000 BTU/h
24 000 BTU/h

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Ascham12eytAscham18eytAscham24eyt

Tabla de contenido