Faults
Control pedal / pumping-up pedal
Switching pedal does not return to initial position
(clamping plate continues to turn).
Control pedal blocked.
Loss of air at one of the pedal cocks.
Tab. 1:
Faults
Robert Bosch GmbH
Malfunctioning | TCE 4460-TCE 4465 | 39
Replace the return spring of the switching pedal.
R Check the condition of the return spring of the plastic locking pawl. Replace
the return spring if necessary.
R Check the condition of the return spring of the pedal. Replace the return
spring if necessary.
R Check the condition of the plastic locking pawl. Replace the plastic locking
pawl if necessary.
R Check whether a defective cylinder is causing the air loss.
R Check whether a defective compressed air connection is causing the air loss.
R Check the condition of the plastic cock. Replace the cock if necessary.
R In the event of a fault at the clamping plate control pedal, check whether the
swiveling collecting pipe is causing the air loss before replacing components
at the pedal.
Remedy
1 695 100 278
en
|
2013-12-03