Note: If a coast-down delay ("SDLY") is
desired after a rinse step, program a
medium-speed spin step for one second after
the rinse step. Then program the desired coast-
down time.

Programming an Auxiliary Step

Auxiliary No. 1 and Auxiliary No. 2 may be
used to control an external buzzer or other
device (not supplied with the machine) with a
maximum current draw of less than 1/2 amp.
Auxiliary No. 3 is identified on the fuse board
as SG (Signal) and controls the built-in buzzer
(alarm) mounted on the inside wall of the
control module.
When A3 is programmed, the signal
will sound continuously for the duration of
time assigned. The same signal (buzzer) is
used by the computer for an alarm condition,
such as a "FILL" or "EMTY" alarm.
When the signal is activated by the computer
to indicate an alarm condition, the tone will be
pulsating rather than continuous.
1. The computer must be in the PROGRAM
mode, and the cycle programming
sequence must be ready for the next step.
2. Press the Auxiliary key. The display will
read "A-nncc." Now press the number
key–1, 2, 3, 4, or 5–that corresponds to the
desired auxiliary function:
A1–Auxiliary No. 1
A2–Auxiliary No. 2
A3–Signal (SG)
A4–Fill to level, using E1 on computer
output board. (E1 is a special function
ONLY. Contact factory for details.)
A5–Provides agitation, no refill.
F232090
Programming
The display will read "A2nncc," for
example, if key 2 is pressed.
3. Press the Enter key. The display will read
"M---S." Now assign the auxiliary step the
desired time in minutes and seconds.
4. Press the Enter key and go to the next step
in the cycle.