MAINTENANCE _____________________________________________________________________________________________________________________________________________________________________________________________________________
Maintenance, cleaning and replacement or repairs shall be done only by personnel familiar with these user instructions and power assisted filtering RPDs, using parts supplied by the original equipment manufacturer.
Prior to use:
Functional inspection of the system
After use:
Cleaning and disinfecting the complete power assisted filtering RPD.
Every 6 years:
Replace the breathing hose o-ring.
STORAGE______________________________________________________________________________________________________________________________________________________________________________________________________________________
Inspect all components prior to storage. Store the RPD in a clean and dry environment as its original packaging or in a sealed container so that it is protected from sunlight, dust or any contaminants. The recommended storage temperature
for Primair 700 Series is -20°C – +35°C and the relative humidity is less than 90%.
TECHNICAL SPECIFICATIONS _________________________________________________________________________________________________________________________________________________________________________________________________
Primair 700 Series
Operating conditions:
Temperature:
-12°C – +48°C
Relative humidity:
20-90%
Storage conditions:
Temperature:
-20°C – +35°C
Relative humidity:
< 90%
Blower unit:
Ingress Protection:
IP65 with battery, breathing tube, filter cartridge and cartridge cover installed
Housing/material:
PC/ABS
Motor life:
>10 000 hours
Noise level:
<75dBA
Flow rate:
180-195-210 lpm
Air hose length:
86 cm/ 100 cm
Hose connection:
bayonet
Weight:
805 g
Altitude:
0 – 3048 m above sea level
Explosive Atmosphere: Do not use.
Connected Blower unit PA710CEU:
Radio frequency:
2.4 GHz
TROUBLE SHOOTING GUIDE __________________________________________________________________________________________________________________________________________________________________________________________________
PROBLEM
Blower will not turn on
Low air-flow alarm is active
Low air flow inside the respiratory interface
Low air flow inside the respiratory interface, but no alarm
Excessive air flow inside the respiratory interface, but no alarm
Caution symbol on display is constantly illuminated (confirmed no low
battery or low flow alarm)
Battery does not hold a charge
Blower unit is not able to pair with the SafetySuite (PA710CEU only)
WARRANTY ___________________________________________________________________________________________________________________________________________________________________________________________________________________
HONEYWELL RESPIRATORY SAFETY PRODUCTS cannot, in general terms, accept responsibility for damage incurred by the owner, user, other persons using the safety product or third parties, which results either directly or indirectly
from incorrect use and/or maintenance of the safety product, including use of the product for any purpose other than that for which it was supplied and/or the non-compliance or incomplete observance of the instructions contained in
this user manual and/or in connection with repairs to the safety product which have not been carried out by us or on our behalf.
HONEYWELL RESPIRATORY SAFETY PRODUCTS will repair or, if necessary, replace this product free of charge in the event of a material or manufacturing defect within 12 months of the purchase date, provided that the product has only
been subjected to normal usage in accordance with the user instructions. The warranty is invalidated if the type or serial number marking is modified, removed or made illegible.
APPROVALS ___________________________________________________________________________________________________________________________________________________________________________________________________________________
Product complies with the European Parliament and Council Regulation 2016/425/EU for Personal Protective Equipment and subsequent amendments. Furthermore, the PA710CEU conforms with the Radio Equipment Directive
2014/53/EU and its subsequent amendments. The EU type-examination as per Module B of PPE Regulation as well as the production process based on quality assurance of the conformity to type set out in Module D of PPE Regulation
are under surveillance of the notified body number 0082:
CLASSIFICATION OF PRIMAIR 700 SERIES: Configuration table based on EN 12941:1998 + A1:2003 + A2:2008
The complete declaration of conformity can be found at: https://doc.honeywellsafety.com/
Battery is not sufficiently charged.
1) Filter has become saturated with contaminates.
2) Breathing hose is obstructed.
3) Cartridge air-inlets are obstructed.
Breathing hose is disconnected or blocked.
1) Breathing hose is partially blocked.
2) Respiratory interface is damaged.
Magnet is missing from the blower-side connector of the breathing hose.
System fault.
1) Battery is nearing the end of its useful life or is damaged.
2) Battery charger is malfunctioning.
Blower unit does not emit the operational data wirelessly.
APAVE SUDEUROPE SAS - CS60193
13322 MARSEILLE Cedex 16 - FRANCE
FILTER
GRIDEL PA710
CC8558939-PA
P R SL
TH3
A2 P R SL
TH3
Battery:
Type:
Li-Ion rechargeable
Material:
Housing: PC/ABS
Latch:
Nylon
Gasket:
Open-cell silicone foam
Weight:
410 g
Capacity:
10.9V, 6700mAh, 73wH
Operating time:
≥8 hours*
Charging time:
4.5 hours
Charging cycles:
> 500 cycles
* Based on laboratory testing.
Battery Charger:
Display:
Real-time battery charge and health monitoring
Power Supply:
AC 100-240V, 1.5A 50-60Hz
Single-bay Charger:
DC 19.0V, 2.37A
Belt and Comfort Pad / Back Pack Materials (Standard version):
Straps:
Woven Nylon
Back/Hip Support:
Thermoplastic Polyurethane, PC/ABS
Comfort Pad:
Closed Cell Polyethylene Foam, Nylon Fabric (TPE Coated)
Back pack:
Thermoplastic Polyurethane (TPU)
POSSIBLE CAUSE
LOOSE-FITTING RESPIRATORY INTERFACE
PRIMAIR VL
PRIMAIR PLUS
A114110
PA111EU / PA121EU
TH2
TH2
TH2
TH2
EN-4
CORRECTION
Replace battery with charged battery.
1) Replace the spoiled filter.
2) Check the breathing hose for blockages or other obstructions.
3) Check to ensure the filter air-inlets are clear of obstructions.
Check breathing hose to ensure there are no blockages inside. Confirm both
ends of the breathing hose are properly connected.
1) Check breathing hose to ensure there are no blockages inside.
2) Replace the respiratory interface.
Replace the breathing hose.
Return the defective unit.
1) Replace the battery with a new one.
2) Replace the battery charger.
Visit https://papr.honeywell.com/ for FAQ and other helpful information, or
contact our SafetySuite support team.
PRIMAIR 800 SERIES
PA810EU
TH2