Internal units
Art. 6302
7
6
5
4
3
1
Monitor description:
1 Privacy service active/system busy/Doctor function active indicator
LED
2 Lock-release activation/door open indicator LED
3 Audio active indicator LED:
The LED flashes to indicate that a call has been received
The LED lights up to indicate that a conversation is in progress
4 Space for additional button installation with accessory Art. 6333
5 Loudspeaker
6 LCD colour display
7 Microphone
Settings:
Knob for ringtone volume adjustment/Privacy service activation
} To increase the ringtone volume, turn clockwise
} To activate the Privacy function, turn fully anticlockwise
» the Privacy active LED will come on
Audio volume adjustment knob
} To increase the value, turn clockwise
Brightness control knob
} To increase the value, turn clockwise
Description of buttons:
Key 1 general actuator (programmable)
1
2
Key 2 self-ignition (programmable)
A Key button
Audio key
1
2
2
Description of monitor
1
2
3
4
5
6
Secondary
1 Terminal block for system connection:
L L Bus line connection terminals
- + Power supply terminals
CFP1 CFP2 Floor door call input
S+ S- Call repetition device terminals
IN1 IN2 Programmable inputs (see page 32)
2 CV6 Selector for using input IN 1 (see page 125)
3 CV5 Jumper for video closure
4 S1 User code programming microswitches
5 SW1 Selector for Simplebus 1 (S1 - default) or Simplebus 2 (S2)
modes
6 S2 Microswitches for programming buttons and functions:
DIP 1-2-3-4 for button function programming
DIP 5-6 access to programming
DIP 7 not used
DIP 8:
ON secondary bracket
OFF main bracket (default)
S 1
S 2
Main