Operating Instructions - Pressure Boosting; Care And Maintenance - Utilitech PPTPC50 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

OPERATING INSTRUCTIONS - PRESSURE BOOSTING

1. Prime and run the pump:
a. Turn the water source on. This will force the pump
(C) to prime.
b. Plug the power cord into a GFCI protected
electrical outlet.
c. When done boosting pressure, immediately
unplug the pump (C).
d. Shut the water supply off.

CARE AND MAINTENANCE

DANGER: Risk of electric shock. Always disconnect the electrical supply before attempting to
install, service, or perform any maintenance. If the power source is out of sight, lock and tag in the
open (off) position to prevent unexpected power application. Failure to do so could result in fatal
electrical shock. Only qualifi ed electricians should repair this unit. Improper repair could result in fatal
electrical shock.
WARNING: Allow the pump to cool for at least 20 minutes before attempting to service. The
motor may be extremely hot. Personal injury may result.
Replacing the Brush
If the pump fails, this could be due to worn brushes or
carbon build-up. Worn brushes are not covered under
warranty.
1. Disconnect the power cord from the power supply.
2. Remove the brush cap (1) with a screwdriver.
3. Remove the old brush assembly (2).
4. Insert a new brush assembly.
5. Replace the brush cap (1).
Caution: There is a brush assembly on both sides of the
motor. Always replace both brush assemblies
at the same time to prevent damage to the
pump.
1
1
8
C
2
Lowes.com
2
1

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

0240050

Tabla de contenido