Installation
Installation
9.
Installation
9.1
Installation instructions
9.1.1 Flow pressure
If the flow rate required for the appliance to switch ON is not
achieved even with the tap fully open, remove the flow limiter.
Replace it with the plastic profile washer supplied. If required the
pressure in the water installation can also be raised.
Thermostatic valves
For the thermostatic valve to function correctly, the flow
limiter for this valve must not be replaced with the plas-
tic profile washer.
Installing flow limiter or plastic profile washer
2
1 Flow limiter
2 Plastic profile washer
9.1.2 Flexible water connection lines
If the appliance is connected with flexible water connection lines,
ensure that the bayonet fittings of the pipe bends do not become
twisted inside the appliance.
www.stiebel-eltron.com
1
10. Assembly
10.1 Installation location
The appliance is exclusively designed for installation on a solid
wall. Ensure the wall offers adequate load bearing capacity.
Always install the appliance vertically (over or undersink) in a
room free from the risk of frost.
10.1.1 Undersink
Undersink installation
1 Cold water inlet
2 DHW outlet
10.1.2 Oversink
Oversink installation
2
1 Cold water inlet
2 DHW outlet
1
2
1
DHB-E electronic |