Installation
Assembly
10.2 Assembly
Opening the appliance
ele ctr on
elec tron
Removing lower part of back panel
f Press the two locking hooks on the r.h. and l.h. side and re-
f
move the lower part towards the front.
Fitting the mounting bracket
f Mark out the holes for drilling using the installation tem-
f
plate. If the appliance is to be installed with water connec-
tions for finished walls, the fixing hole in the lower part of
the template must also be marked out.
f Drill the holes and secure the mounting bracket with
f
two screws and two rawl plugs. The screws and rawl plugs
are not part of the standard delivery.
8
|DHB-E electronic
ic
ic
Fitting the power cable
160
30
f Prepare the power cable.
f
f Use the plastic cap as an installation aid.
f
Sealing in and inserting twin nipples
Water connection
1
2
1 Tee
2 Cross-piece
f Secure the tee and cross-piece to the twin nipples with
f
flat packing.
f Thoroughly flush the cold water supply line.
f
Three-way shut-off valve
Never use the three-way shut-off valve to reduce the
flow rate. It is designed exclusively for shutting off the
line.
Fitting the sieve
f Fit the sieve provided in the cold water inlet of the appliance.
f
Sieve
The sieve must always be fitted for the function of the
appliance to be guaranteed. If an appliance is being
replaced during installation, ensure that a sieve is avail-
able.
www.stiebel-eltron.com