Sensor Calibration - Pulsar ACCOLADE 2 LRF Manual Del Usuario

Ocultar thumbs Ver también para ACCOLADE 2 LRF:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
WARNING!
The radiator cooling system (12) becomes warm during
operation: this is normal and allows an increase in the sensitivity
of the device.
Powering on and image setup
Open the lens cover
(13)
.
T
urn the
device
on with a short press of the
Adjust the interpupillary distance with the rings (6) by moving the
eyepieces farther or closer to each other.
To obtain a crisp image of the icons on the display, rotate the dioptre
adjustment ring
s (7) Once adjusted,
.
dioptre adjustment ring for distance or any other conditions.
To focus on the object being observed rotate the lens focusing
ring
(8)
.
To set up display brightness and contrast and continuous zoom,
please refer to the
QUICK
MENU FUNCTIONS section.
A
fter use,
press and
hold down the
device off.

SENSOR CALIBRATION

Calibration allows levelling of the background temperature of the
microbolometer and eliminates image flaws (such as frozen image,
vertical stripes etc.).
There are three calibration modes:
manual (M), semi-automatic (SA) and automatic (А).
Select the desired mode in the menu option «CALIBRATION»
Mode М (manual)
- Close the lens cover, press briefly the ON/OFF (1) button.
- Open the lens cover.
Mode SA (semi-automatic)
- Press briefly the ON/OFF button to calibrate.
- You do not need to close the lens cover (the sensor is closed with
the internal shutter automatically).
Mode А (automatic)
- The device calibrates by itself according to the software
algorithm.
You do not need to close the lens cover (the sensor is closed with
the internal shutter automatically).
- In the automatic mode the user can calibrate the sensor with the
ON/OFF (in the SA mode) button.
ON/OFF (1)
button.
there is no need to rotate the
ON/OFF
button to turn the
10
INCREMENTAL DIGITAL ZOOM
The device allows you to quickly increase the basic magnification
(please refer to the
«Digital zoom»
4 or 8 times.
To operate the discrete digital zoom, press successively the DOWN (5)
button.
The digital zoom will not be saved after the device is re-started.
11
IMAGE DETAIL BOOST
The "Image Detail boost" function increases the sharpness of the
contours of heated objects, which increases their detail. The result of the
function depends on the selected mode and observation conditions: the
higher the contrast of objects, the more noticeable the effect. This option
is enabled by default, but can be disabled in the main menu.
12
QUICK MENU FUNCTIONS
The Quick menu allows change of basic settings such as display
brightness and contrast, smooth digital zoom.
Enter the menu with a short press of the М (3) button.
To toggle between the functions below, press successively the M
button.
Brightness
– press briefly the UP(2)/ DOWN(5) buttons to
change display brightness from 00 to 20.
Contrast
– press briefly the UP(2)/ DOWN(5) buttons to change
display contrast from 00 to 20.
Smooth digital zoom
change digital zoom from 2,5 to 20.
Smooth digital zoom is in 0.1x increments.
Basic mode
– it allows you to select one of the three modes
as the basic one for the user mode.
Notes.
- actual magnification is the product of the basic magnification value
and continuous digital zoom value.
For example: the device's basic magnification is 3.
zoom value 1.7. Actual magnification is 5.
х
line in the specifications table) by 2,
– press the UP(2)/
DOWN
(5) buttons to
, smooth digital
(3. *1.7).
1
5
Tabla de contenido
loading

Tabla de contenido