Never use a modified or damaged charger.
Do not leave the Battery Pack with a charger connected to the
mains longer than 24 hours after full charge.
Do not expose the battery pack to high temperature or to a naked
flame.
Do not submerge the battery in water.
Do not connect external device with a current consumption that
exceeds permitted levels.
The Battery Pack is short circuit protected. However, any situation
that may cause short-circuiting should be avoided.
Do not dismantle or deform the Battery Pack.
Do not drop or hit the battery.
When using the battery at negative temperatures, battery's capacity
decreases, this is normal and is not a defect.
Do not use the battery at the temperatures above those shown in
the table – this may decrease battery's life.
Keep the battery out of the reach of children.
7

EXTERNAL POWER SUPPLY

The device can be powered with an external power supply such as
Power Bank (5V).
Connect the external power supply to the USB port (15) of the device
(Pic. 1 on the flyleaf).
The device switches to operation from external power supply, and the
IPS5 Battery Pack will begin slowly charging.
The display will show the battery icon
percentage.
If the device operates on external power supply but the IPS5 battery is
not connected, the icon
When the external power supply is disconnected, the device switches
to the internal battery pack without powering off.
7
6
with charge level as a
is shown.
8
OPERATION
WARNING! Do not point the objective lens of the device at intensive
sources of light such device emitting laser radiation or the sun. This
may render the electronic components inoperative. The warranty
does not cover damage caused by improper operation.
WARNING! The radiator cooling system (12) becomes warm during
operation: this is normal and allows an increase in the sensitivity of
the device.
Powering on and image setup
Open the lens cover
(13)
.
T
urn the
device
on with a short press of the
Adjust the interpupillary distance with the rings (6) by moving the
eyepieces farther or closer to each other.
To obtain a crisp image of the icons on the display, rotate the dioptre
adjustment ring
s (7) Once adjusted,
.
dioptre adjustment ring for distance or any other conditions.
To focus on the object being observed rotate the lens focusing
ring
(8)
.
To set up display brightness and contrast and continuous zoom,
please refer to the
QUICK
A
fter use,
press and
hold down the
off.

SENSOR CALIBRATION

Calibration allows levelling of the background temperature of the
microbolometer and eliminates image flaws (such as frozen image,
vertical stripes etc.).
There are three calibration modes:
manual (M), semi-automatic (SA) and automatic (А).
ON/OFF (1)
button.
there is no need to rotate the
MENU FUNCTIONS section.
ON/OFF
button to turn the
device
8