Fireplace Installation
deep. The viewing area is
30 ⅛ in. (765 mm) wide and
20 ⅛ in. (511 mm) high. The
fireplace does not require any
additional venting. (See Figure
1 for recommended installation
clearances.)
Mantel Installation
Install the fireplace assembly into
the mantel (refer to mantel as-
sembly instructions).
!
IMPORTANT:
Dimplex mantel, the fireplace
must be installed in an enclo-
sure with the following MINI-
MUM internal/opening dimen-
sions (Figure 1A).
New Wall Construction
1. Mark the desired location on
the floor and store the fire-
place in a safe, dry and dust
free location.
2. Use studs to frame an opening
Wiring
8
If not using a
of 30 ½ in. (775 mm) wide x 25
¾ in. (654 mm) high x 11 ¾ in.
(298) deep. (Figure 1B)
3. Plug the unit into a 15 Amp/
120 Volt outlet.
Option #1: The power cord can
be lead from behind the trim
and along the wall to an outlet
near the fireplace.
Option #2: A new outlet can be
installed inside the new frame
construction.
!
NOTE:
A 15 Amp, 120 Volt
circuit is required. A dedicated
circuit is preferred but not es-
sential in all cases. A dedi-
cated circuit will be required
if, after installation, the circuit
breaker trips or fuse blows
on a regular basis when the
heater is operating. Additional
appliances on the same circuit
may exceed the current rating
of the circuit
LOGSET LED LIGHTS
breaker.
www.dimplex.com