Installation Instructions - Cardin Elettronica SLX Serie Manual De Instrucciones

Ocultar thumbs Ver también para SLX Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
PRELIMINARY CHECKS (fig. 1, pag. 2)
Before starting the installation make sure that the structure which
is to be automated is in good working order and respects the
local standards and regulations in force.
To this end ensure that:
- the surface of the sliding gate "A" is smooth and has no
protrusions up to a distance of 2,5 m from ground level.
Protrusions on the gate surface which are not greater than 3
mm and have rounded edges are acceptable.
If the surface of the gate is not smooth, the entire height up
to 2,5 m from the ground must be protected by two of the
following devices:
a) photoelectric cells
b) contact safety buffer;
- the distance 'B' between the fixed parts and sliding parts of
the installation must not exceed 15 mm;
- the runner guide 'C', preferably round, should be securely
fixed to the ground, completely exposed and free of any
imperfections which could inhibit the correct movement of
the gate;
- when the gate is closed a space of 50 mm 'D' must remain for
the entire height of the front part of the gate and a mechanical
travel limit 'E' must be positioned on the upper part of the
gate.
• The free space 'D' can be covered with a rubber anti-crush
buffer 'F' or better still a pneumatic or photoelectric contact
safety buffer.
• If the gate slides past a fixed structure 'G' which has railings
or bars leaving open spaces, it must be protected in one of

INSTALLATION INSTRUCTIONS

Overall dimensions and positioning
• The geared motor must be correctly positioned when it is installed: perpendicular to the ground and straight up on flat ground.
30
340
330
5
256
56
240
65
25
5
the following ways:
- distance 'H' greater than 500 mm: no protection required;
- distance 'H' between 500 and 300 mm: wire mesh fencing
'I' or punched metal plating 'L' with an opening which does
not allow the passage of a 25 mm diameter sphere 'M' must
be fitted;
- distance 'H' smaller than 300 mm: wire mesh fencing 'I' or
punched metal plating 'L' with an opening which does not
allow the passage of a 12 mm diameter sphere 'M' must be
fitted.
The wires of the mesh 'I' must not have a cross-section of
less than 2,5 mm
not have a thickness of less than 1.2 mm. Protection is not
necessary for the area 'P' if the fixed structure with railings
or bars is over 2,5 m above the ground.
• Check the gate components, replace any worn or damaged
parts and then lubricate them.
• Using a spirit level 'N' check that the castor guide is in square.
• The upper runner guide 'O' must have the correct play for
the gate and must not inhibit the gate's sliding action.
• Check that a mechanical travel limit 'Q' (absolutely necessary)
has been fitted in the opening direction and that it corresponds
to the maximum travel distance 'P' of the gate. The travel limit
must guarantee anti-derailment and gate stability.
Warning! It is the installer's responsibility to check all
critical danger points, to take action and to install any
devices needed to guarantee the safety of all people
using the gate (risk analysis).
170
170
165
165
- The geared motor unit has been assembled in the factory
to be fitted to the LEFT SIDE of the gate (internal view).
To install the motor to the right set the installation parameter
in the instruction manual MULTI-ECU SOFTWARE ZVL608
supplied with the automation.
11
and the punched metal plating 'L' must
2
SLX3024 - 3000 kg
perpendicular
to the ground
SLX1524 - 1500 kg
SLX824 - 800 kg
perpendicular
to the ground