11 Dismounting
Fault
Problem when
mounting the cable
assembly into the
iSTM mount
Hose assembly makes
ripples in the robot
axis
Inaccurate
torch reset
11 Dismounting
DANGER
Risk of injury due to unexpected start-up.
Improper operation can lead to serious injuries that could result in death.
For the entire duration of maintenance, servicing, dismounting and repair work, the following
instructions must be adhered to:
• Switch off the power source.
• Close the gas supply.
• Close off the compressed air supply.
• Close off the coolant supply.
• Disconnect all electrical connections.
• Switch off the entire welding system.
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Consult the documentation for the welding components.
• Observe the information given in section
 8 Putting out of operation on page EN-16.
1 Disconnect the cable assembly from the wire feeder.
2 Open the lock ring, unscrew the fastening screw.
 6.2.2 Mounting the cable assembly on the robot on page EN-11
3 Pull out the cable assembly.
EN - 20
Cause
• No grease on the O-rings of
the adapter
• The cable assembly adapter
is not correctly inserted into
the module
• Cable assembly too long
• Dirt deposits in the housing
• iSTM mount damaged
Solution
• Lubricate the O-rings with
grease
• Use the cable setting tool
• Align the guide groove
• Change the feeding system
positioning, if possible
• Remove dirt deposits and
clean the housing
• Seal if off with bellows
• Check by specialized
personnel