Storage; Unpacking; Vacuum Pump - Parker PNEUDRI MXLE ADVANTAGE Serie Manual De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 227

2.7.1 Storage

The equipment should be stored, within the packing crate, in a clean dry environment. If the crate is stored in an area where the environmental
conditions fall outside of those specified in the technical specification, it should be moved to its final location (installation site) and left to stabilise
prior to unpacking. Failure to do this could cause condensing humidity and potential failure of the equipment.

2.7.2 Unpacking

Remove the lid and all four sides of the packing crate (A) and unscrew the exhaust silencer from the dryer (B). Lift the dryer on to its feet using
suitable slings and an overhead crane (C, D and E).
Carefully move the dryer to its final location, using a forklift truck or pallet truck, and refit the silencer (F).
A
D

2.7.3 Vacuum Pump

The vacuum pump is supplied separately from the dryer. Check that the pump supplied corresponds to the pumps referenced below:-
Dryer
MXLE 102C
MXLE 103C
MXLE 103
MXLE 104
MXLE 105
MXLE 106
MXLE 107
MXLE 108
10
B
E
Vac Pump 1
Vac Pump 2
U4.165
U4.165
U4.190
U4.250
U4.300
U4.190
U4.190
U4.250
U4.190
U4.250
U4.250
-
-
-
-
-
C
F
Tabla de contenido
loading