Useful Information
Draining the Water to Prevent Freezing
1 Set the 【Seat Temp.】 to "High" and close
lid ( ☞ Page 9).
the SpaLet
®
2 Turn off any active power save function
( ☞ Page 21).
3 Manipulate the water drain plug in your
building to drain water from the pipes.
* Do not close the water shutoff valve when
manipulating the water drain plug.
4 Press the 【Flush Full】 button or press the
flush button on the SpaLet body.
* Wait approximately 20 seconds.
* Confirm that the water does not flow when
attempting to flush the SpaLet.
5 Drain water from the SpaLet body
* Refer to steps 3 and 4 of the "Draining Water"
procedure on page 43 to drain the water from the
SpaLet bowl.
6 Reattach the side cover ( ☞ Page 42).
■ Reusing the SpaLet
Always perform the necessary preparations and
checks before use. ( ☞ Page 7)
31 - EN
■ If water has frozen and the SpaLet does not
operate or if the water supply hose or water supply
connections have frozen and the SpaLet does
not operate, use a cloth immersed in warm water
to warm the water supply hose or water supply
connections to slowly thaw them, or warm the
bathroom and allow them to thaw naturally.
[CAUTION]
● Do not pour hot water or blow hot air over the
water supply hose.
* Doing so may result in damage to the water
supply hose.
● Water may be discharged during the thawing
process depending on the parts being warmed.
Confirm the condition regularly during the thawing
process.