Chapter 2. How to Configure and Program the Control
Rotating—The operator signal sounds, and the basket rotates clockwise at wash speed.
Tumble—The operator signal sounds, and the basket reverses at wash speed. You can open the
door to remove part of the load, then press the Start button to resume basket rotation.
Stop + Signal—The operator signal sounds and the basket coasts to a stop. The operator signal
stops sounding after 2 minutes.
Reversing + Signal—The operator signal sounds, and the basket reverses for 20 seconds in each
direction with 3 seconds of dwell time between reversals. The operator signal stops sounding
after 2 minutes.
Rotating + Signal—The operator signal sounds, and the basket rotates clockwise at wash speed.
The operator signal stops sounding after 2 minutes.
Tumble + Signal—The operator signal sounds, and the basket reverses at wash speed. You can
open the door to remove part of the load, then press the Start button to resume basket rotation.
The operator signal stops sounding after 2 minutes.
On Time
2.2.14.
When a bath step turns in two directions, this is the number of seconds the motor is ON, turning
the basket.
Off Time
2.2.15.
When a bath step turns in two directions, this is the number of seconds the motor is OFF, letting
the basket coast.
Fill from Tank
2.2.16.
If the machine is equiped with an overhead tank, fill from the tank for this step.
Recirculate Water
2.2.17.
If the machine is equiped with recircluation piping, circulate the bath liquor out of the machine,
through other devices, and back into the machine.
BICLWC02 (Published) Book specs- Dates: 20170301 / 20170301 / 20170301 Lang: ENG01 Applic: CLW
2.3. How to Calibrate the Flow Meter
The flow meter measures the quantity of water as it flows into the machine cylinder for a bath
step. The MilTouch controller uses the value reported by the flow meter to close the water valves
when the desired amount of water per weight unit of goods is achieved. Any unit can be used for
the water unit, but the controller prompts for the actual weight of goods in each load.
Supplement 4
Gallons (US) = 0.264 x Liters or Kilograms
PELLERIN MILNOR CORPORATION
— End of BICLUP01 —
Common Unit Conversions
Gallons (US) = 0.12 x Pounds (US)
Kilograms = 1.0 x Liters
Kilograms = 0.454 x Pounds (US)