Tabla de contenido
4. Connect hoses to nozzles by pushing each hose
over nozzle lip. Hoses should fit snugly onto
nozzles and then secured with proper clamps.
NOTE: Do not attempt to make chemical injection
supply pump electrical connections to points other
than those provided specifically for that purpose by
the factory.
Machines connected to 200VAC provide L1 and L2
fused outputs rated at 3 amps which may be used to
power 208 – 240VAC supply pumps.
Machines connected to 400VAC do not provide L1 and
L2 outputs. An external power source must be
provided to power the chemical supply pump.
Do not use L1 or L2 with the common line to deliver
120VAC to chemical injection supply pumps if the
machine is equipped with a control transformer.
CAUTION
Dangerous Voltages. Will cause damage
to the machine and microprocessor. Do
not attempt to obtain 110VAC by using L1
or L2 with the common. Do not use a
240VAC power wire in the washer-
extractor and an earth ground to obtain
110VAC.
Consult the supply vendor instructions for operational
details about supply injections.
125 Pound OPL Models
(With Optional Dispenser)
Refer to Figure 23.
1. Remove plugs from base. Plugs are assembled
inside tubing ring.
2. Install strain reliefs included in seal nut.
3. Insert tubes through base. Do not remove dry
supply cups. Tube should extend into plastic cup,
with exception of softener tube, which should be
routed to outside of cup.
4. Tighten seal nut to prevent tubing from escaping
assembly.
F232135
W365
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Terminals SUPPLY 1 through SUPPLY 5 provide
120VAC or 240VAC fused at 500mA. Refer to decal at
external supply terminal strip to determine whether
washer-extractor provides 120VAC or 240VAC. These
terminals may be used to provide signals to chemical
injection supply system but must not be used to
provide power to actual pump.
IMPORTANT: Increasing fuse rating may cause
damage to washer-extractor's circuitry.
IMPORTANT: Any injection system pump that
requires 110VAC must be powered by a separate
external power source.
Consult chemical injection supply system instructions
for operational details.
1
Strain Relief for Liquid Chemical Supply
Lines
2
Supply Dispenser Lid
3
Dry Supply Cups
4
Dry Supply Insert
5
Four Way Water Valve
6
Supply Dispenser
Figure 23
Installation
1
2
3
4
5
6
P048I
P048I
39