①
Key cover
②
Cover (front), optionally with inspection window
③
Door contacts (front and rear)
Optional: The installed cover catches depend
on the type of protection.
Figure 4-2
View of the pressure transmitter: Left: Front right: View from rear
5
Commissioning
5.1
Basic safety instructions
DANGER
Toxic gases and liquids
Danger of poisoning when venting the device: if toxic process media are measured, toxic gases and liquids can be
released.
Before venting ensure that there are no toxic gases or liquids in the device, or take the appropriate safety measures.
•
WARNING
Improper commissioning in hazardous areas
Device failure or danger of explosion in hazardous areas.
Do not commission the device until it has been mounted completely and connected in accordance with the information
•
in Chapter "Technical data (Page 27)".
Before commissioning take the effect on other devices in the system into account.
•
18
④
Blanking plug
⑤
Cover (rear) for electrical terminal compartment
⑥
Cable gland
SITRANS P500 with HART
A5E02344532-04, 12/2014