The circulator must be connected to an external main switch with a minimum contact distance of 3 mm on all
poles. It is possible to use the earthing or the neutralisation as protection against indirect contact.
It is recommended to install a differential switch to protect the system, which must
have correct dimensions, such as: Class A with adjustable leakage current, selective,
protected against sudden tripping.
The automatic differential switch must be marked with the following two symbols:
The circulator does not require any external motor protection.
Ensure that the supply voltage and frequency are the same as the values indicated on the electrical
data plate of the circulator.
ENGLISH

Figure 3: Electrical connections (front)

31