• On any given dive, both divers in a buddy pair must follow the most conservative dive
computer for that particular dive.
• Never dive without a buddy. Aladin 2G does not substitute for a dive buddy.
• Only make dives that are appropriate to your level of dive training. Aladin 2G does not
increase your knowledge of diving.
• Always dive with back-up instruments. Make sure that you always use back-up
instrumentation including a depth gauge, submersible pressure gauge, digital bottom
timer or dive watch, and have access to decompression tables whenever diving with a
dive computer.
• Avoid repeated ascents and descents (yo yo diving).
• Avoid repeated heavy workload while at depth.
• Plan the dives to be shorter if they are made in cold water.
• After finishing the decompression or at the end of a no-stop dive, the final stage of the
ascent should be as slow as possible.
• You MUST be familiar with all signs and symptoms of decompression sickness before
using Aladin 2G! Seek IMMEDIATE treatment for decompression sickness should any
of these signs or symptoms occur after a dive! There is a direct correlation between
the effectiveness of treatment and the delay between the onset of symptoms and the
treatment for decompression sickness.
• Only dive with Nitrox after you have been thoroughly instructed by a recognized
institution.
Repetitive dives
• Do not start your next dive before your CNS O
• When diving with Nitrox, make sure your surface interval is long enough (just like diving
with compressed air). Plan for a minimum surface interval of two hours. Oxygen, too,
needs sufficient time to leave the body.
• Match gas mixture to the intended dive.
• Do not attempt a repetitive dive if the no-dive warning
• Plan a day without diving once a week.
• If you have to change computers, wait at least 48 hours before carrying out your next
dive.
• Diving after a reset of the remaining saturation (reset, see page 62, or battery
replacement, see page 68) may lead you into potentially hazardous situations which could
result in death or serious injury. After a reset of the remaining saturation do not dive for
at least 48 hours.
Altitude and diving
• Do not dive at altitudes higher than 4000m (13000ft).
• After a dive do not rise to altitudes that Aladin 2G prohibits
via the flashing altitude range number (see page 31).
Flying after diving
• After diving, wait at least 24 hours prior to flying.
Aladin 2G dive instrument is a personal protective equipment in compliance with the essential safety requirements of the
European Union directive 89/686/EEC. RINA SpA, Via Corsica 12, I-16128 Genoa, notified body no. 0474, have certified
the conformity with the European Standard EN 13319:2000.
EN13319:2000 Diving accessories - Depth gauges and combined depth and time measuring devices - Functional and
safety requirements, test methods. Any information on decompression obligation displayed by equipment covered by this
standard is explicitly excluded from its scope.
2
% status has dropped below 40%.
2
is visible on the display.
5. 2010
SCUBAPRO ALADIN 2G