Partial Pressure Of Oxygen (Ppo 2 Depth (Mod) - Scubapro Aladin 2G Manual De Usuario

Ocultar thumbs Ver también para Aladin 2G:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 151
• Display of the ascent rate has the
priority over "CNS O
Ascent rate
Visual alarm
S
L
%
O
W
S
L
%
O
W
S
L
%
O
W
S
L
%
O
W
Reduce ascent rate
Excessive ascent rates for longer periods
are entered in the logbook.
The following ascent rates correspond to
the 100% value in Aladin 2G.
depth (m)
speed (m/min)
<6
7
<12
8
<18
9
<23
10
<27
11
<31
13
<35
15
<39
17
<44
18
<50
19
>50
20
SCUBAPRO ALADIN 2G
".
2
WARNING
Audible alarm
depth (ft)
speed (ft/min)
<20
23
<40
26
<60
29
<75
33
<88
36
<101
43
<115
49
<128
56
<144
59
<164
62
>164
66
3. Diving with Aladin 2G
3.4.7 Partial pressure of oxygen
(ppO
max) / Maximum
2
Operating Depth (MOD)
4s
DEPTH
DIVE TIME
NO STOP
CNS O
Max Operating Depth MOD
The maximum partial pressure of oxygen
ppO
max (default 1.4bar) determines the
2
Maximum Operating Depth (MOD). Diving
deeper than the MOD will expose the diver
to oxygen partial pressures higher than the
set maximum level.
The ppO
max and consequently the MOD
2
can be reduced manually (->21, setting the
gas mixture, point 5).
In addition the maximum allowed ppO
be set by means of SmartTRAK or with
"set 1" between 1.2 to 1.6 bar ->59.
WARNING
The MOD is a function of ppO
mixture used. If during the dive the MOD is
reached or exceeded Aladin 2G sends an
audible attention message and the MOD is
displayed (flashing) in the lower left corner.
Ascend to a depth shallower than the displayed
MOD in order to diminish the danger of oxygen
poisoning.
WARNING
The MOD should not be exceeded. Disregarding
the warning can lead to oxygen poisoning.
%
2
can
2
max and the
2
25
Tabla de contenido
loading

Tabla de contenido