HeatStar HSU50 Instrucciones De Funcionamiento Y Manual Del Propietario página 15

Ocultar thumbs Ver también para HSU50:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

FUEL CONVERSION Section 2: FUEL CONVERSION INSTRUCTIONS
WARNING: Explosion Hazard
Turn off the gas supply to the heater before perform-
ing any service or maintenance.
Failure to follow these instructions will result in death,
injury or property damage.
WARNING: Electrical Shock Hazard
Unplug the electrical cord from the outlet before
performing any service maintenance.
Failure to follow these instructions will result in death,
injury or property damage.
The electrode and sensor are not adjustable. DO
NOT change location or position as part of this
conversion kit.
This conversion kit shall be installed by a qualified service
agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority
having jurisdiction. If the information in these instructions is
not followed exactly, a fire, explosion or production of carbon
monoxide may result causing property damage, personal injury
or loss of life. The qualified service agency performing this work
assumes responsibility for the proper conversion of this appliance
with this kit.
FIGURE 10
WARNING
Compact Unit / Utility Heater
4 screws
Step 1
CAUTION THE UNIT MUST NOT BE CONNECTED TO EITHER
THE GAS SUPPLY OR THE ELECTRICAL POWER SUPPLY, BEFORE
PROCEEDING WITH CONVERSION.
Step 2
Remove and retain the four screws holding the manifold on to the
burner box (Figure 10). Rotate the valve/ manifold assembly, away
from the burners (Figure 11). The valve/manifold assembly holds the
orifices (3 orifices on unit HSU50, 5 orifices on unit HSU80, 8 orifices
on unit HSU125). This will allow access to the orifices on the manifold,
and also the adjustment spring in the valve/regulator.
Step 3
Remove and discard the adjustment spring cap from gas valve/
regulator with a flat blade screw driver by turning the screw counter-
clockwise. Remove and discard the regulator adjustment screw found
under the cap. Remove and discard the spring that is located under
the adjustment screw. Take the spring kit from the conversion kit,
and compare the part number of the kit to the parts list on page 3. If
it does not match, immediately contact Heatstar, Inc. for the correct
kit. After confirming the spring kit is correct for the heater model you
are converting, install the new spring and adjustment screw. Turn
spring adjustment screw clockwise (in) until the screw stops, then turn
it counter-clockwise (back) 1 ½ turns. Place conversion label supplied
with the spring kit on the valve near the adjustment screw cover
opening.
Step 4
Remove and discard the orifices (3 orifices on unit HSU50, 5 orifices
on unit HSU80, 8 orifices on unit HSU125) from the manifold with
using a ½ " open end wrench. Turn them counter-clockwise to
remove. Take the new orifices from the conversion kit and before
installing, confirm that the number stamped on the side of the
orifice matches the number for the kit being installed. If it does not,
immediately contact Heatstar, Inc. for the correct kit. If they are the
correct orifices, install them in the manifold using caution not to cross
thread.
15
Operating Instructions and Owner's Manual
FIGURE 11
Tabla de contenido
loading

Este manual también es adecuado para:

Hsu80Hsu125Hsu 50

Tabla de contenido