Welding Process; Putting Out Of Operation - Abicor Binzel 241 Instructivo De Servicio

Mig/mag robo antorcha de soldadura
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MIG/MAG ROBO welding torch

7.1 Welding process

8 Putting out of operation

DANGER
Risk of burns
During welding sparks, glowing workpieces or hot slag can produce flames.
• Check the work area for flashpoints.
• Provide suitable fire extinguishing equipment at the workstation.
• Allow workpieces to cool down after welding.
• Prior to performing welding work, properly fasten the ground clamp to
the workpiece or the welding table.
WARNING
Arc eye
The arc produced by welding can damage the eyes.
• Wear protective clothing and eye protection.
NOTICE
• The device may only be operated by qualified personnel (in Germany
see TRBS 1203).
• Never pull the cable assembly across sharp edges or place it in the
welding spatter area or on hot workpieces.
• Ensure that all required parameters, for example welding current, wire
feed, etc., have been set at the welding power source according to your
welding task.
1 Open the shielding gas cylinder.
2 Switch on the power source.
NOTICE
• When putting the system out of operation, ensure that the procedures for
switching off all the welding system components are observed.
1 Wait until the shielding gas post-flow time has expired.
2 Close the shut-off valve for the gas supply.
3 Switch off the power source.
8 Putting out of operation