4) Check the battery voltage; it must be at least 12,5 Volts. Charge if necessary.
If the battery has been supplied dry with the acid separate, to put it into service proceed as
follows:
1) Add the acid and wait 2 hours.
2) Charge the battery with a battery charger set at 12 Volts on slow charge for 2 hours.
Caution; failure to follow this rule may cause deterioration of the battery and acid leaks during
operation.
IMPORTANT!!! During assembly take care not to reverse the polarity of the battery.
BATTERY - CAUTION!
The gases released by the battery are explosive, keep it away from naked lights or sparks. Check the
liquid level periodically and keep the terminals lubricated with Vaseline grease.
RUNNING IN - CAUTION!!
the wheels. Adjust the tension of the hydrostatic transmission belts (Fig. 16).

INSTRUCTIONS FOR USE

Before starting up the engine, always check that:
– the engine oil level is correct (Fig. 2);
– the oil in the hydraulic motor is at the correct level (Fig. 3);
– the travel lever is in the idle position (2, Fig. 1/B);
– the engine cooling intake grilles are clean (Fig. 5);
– the mowing deck is clean;
– the screw in the centre of the blade hub is securely tightened (3, Fig. 1/C)
STARTING UP THE ENGINE
– Push the throttle half way in (5, Fig. 1/B)
– If the engine is cold, use the choke (6, Fig. 1/B). Turn the ignition key on the dashboard (7, Fig. 1).
– Once the engine has started, turn off the choke and wait for a few minutes to allow the engine to warm up.
N.B. When moving the mower from one place to another, you are advised to keep the cutting deck at
the maximum height setting.
STARTING WORK
– Choose the desired cutting height by means of the lever 8 Fig. 1/D. Suitably accelerate the engine
and engage the PTO lever (1, Fig. 1). Gently operate the forward travel lever (2, Fig. 1/B) and start
work. To stop, return the forward travel lever to the stop position.
– The lever (2, Fig. 1/B) is also used to reverse. When it is moved back, the machine moves backwards;
always operate it gently.
FRONT BRAKE
The front brake (Fig. 23 n. 1) must be used only as an emergency brake sloping down, to avoid the machine
sliding. (When it is used with the differential lock, it makes the machine steadier sloping down).
The forward travel lever is normally used to decelerate and to brake.
PARKING BRAKE
To engage the parking brake, please press the lever downwards and lock it to the proper seal retainer