Prepare The Receiver Collar; To Insert And Remove The Receiver Collar Battery; To Set The Static Correction Level - Petsafe HIG11-13655 Manual De Adiestramiento Y Funcionamiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Prepare the
Step
5
Receiver Collar
Your Receiver Collar comes with short Contact Points installed.
Use the long Contact Points for pets with long or thick hair.
Tighten the Contact Points using the Test Light Tool (5A) one-
half turn beyond finger tight. Check the tightness weekly.
To Insert and Remove the
Receiver Collar Battery
Note: Do not install the battery while the Receiver Collar is on
your pet.
This Receiver Collar utilizes a replaceable PetSafe
(RFA-67). This unique battery is designed to make battery
replacement easier and increase water protection.
To insert the battery, align the symbols on the battery (arrow)
and Receiver Collar (triangle) (5B). Use the edge of the Test Light
Tool (5A) to turn the battery clockwise until the arrow lines up
with the lock symbol on the housing.
To remove the battery, turn the battery counter-clockwise using
the edge of the Test Light Tool (5C). DO NOT attempt to cut into or pry open the battery.
Be sure to discard the used battery properly. Battery life will vary depending on how often
your pet tests the system and receives a Static Correction. Check the Receiver Collar every
month to ensure the battery is working properly.
If the Receiver LED Indicator Light is flashing every 4 to 5 seconds, battery replacement is
required. Remove the old battery from the Receiver Collar. Discharge all power by holding
the correction level button down until the LED is no longer illuminated. Replace with a new
battery.
A replacement PetSafe
Customer Care Center or visit our web site at www.petsafe.net to locate a retailer near you.

To Set the Static Correction Level

Read all steps before attempting to set the Static Correction Level.
1. Remove the clear plastic cover with the Test Light Tool to
expose the Correction Level Button (5D).
2. With the battery installed, press the Correction Level Button
and release when the Receiver Indicator Light lights up (5E).
3. The Receiver Indicator Light will emit a series of flashes
representing the Static Correction Level.
4. Increase the Static Correction Level by pressing and releasing
the Correction Level Button within 5 seconds of the previous
series of flashes.
5. After setting the Static Correction Level, replace the cover to
protect the Correction Level Button.
The Static Correction levels increase in strength from 1 to 5.
Pushing the Correction Level Button while the Receiver Collar is on
level 5 will cause the Receiver Collar to revert to Level 1. Refer to
the Function and Response Table to choose the Static Correction
level that best fits your pet.
The Receiver Collar is equipped to automatically increase the
level of Static Correction the longer your pet remains in the Static
Correction Zone if the collar is set at level 2 or above.
The Receiver LED Indicator Light acts as a low battery indicator,
flashing every 4 to 5 seconds when replacement is required.
battery (RFA-67) can be found at many retailers. Contact the
®
www.petsafe.net
5A
5B
battery
®
5C
5D
5E
15
Tabla de contenido
loading

Tabla de contenido