DESCRIPTION OF THE CONTROL UNIT
• 230V - 50Hz or 120V - 60Hz power supplies, depending on the
model, for 1 single phase motor (700W).
• 2 inputs for key selector switch or button activation.
• Programmable operational logic JUMPER (J1).
• Provided with a 433.92 MHz super-heterodyne radio receiver.
• Functioning by means of Personal Pass transmitters.
ELECTRICAL CONNECTIONS
Connections for operation with 2 buttons (Fig.1)
Connections for operation with 1 button (Fig.2)
1
GND earth cable
2
Neutral feed
3
Live feed
4
Motor common ground
5
Motor closed
6
Motor open
7
Open button
8
Open button common ground
9
Close button common ground
10
Close button
FIG.1
START (OPEN)
START (CLOSE)
FIG.2
START
J1
7
8
9
10
ANT
J1
7
8
9
10
ANT
TECHNICAL SPECIFICATIONS
Power supply
Max motor load
Working temperature
Dimensions / Weight
Protection
WORKING TIME OF MOTOR
The control unit stops the motor movement after 2 minutes: in
case of limit switches malfunction this "time out" avoids the
motor overheating.
- 5 -
230V models
120V models
230 V / 50 Hz
120V / 60Hz
700 W
700 W
-20 ÷ +60 °C
127 x 41 x 24 mm / 100 g
IP55
1
GND
N
2
N
3
L
F
4
COM
M
(F)
5
CLOSE
6
OPEN
1
GND
N
2
N
3
L
F
4
COM
M
(F)
5
CLOSE
6
OPEN