Xylem LOWARA Q-Smart Manual De Instalación, Funcionamiento Y Mantenimiento página 47

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 118
In sewage application (c02=0), all pumps are
switched ON.
In lifting application (c02=1), all pumps are
stopped.
The alarm is excluded in manual mode.
Causes/solutions
The level has reached the position of float
switch G MAX or probe S MAX if used. The
pumps might not run.
If the alarm appears but the level has not
reached float switch G MAX or probe S MAX:
Float switch G MAX is damaged and
o
must be replaced.
Probe S MAX is damaged and must be
o
replaced.
The cable of the float switch is faulty or
o
worn, replace it.
The cable of the probe is faulty or worn,
o
replace it.
Check connection of float switch G MAX
o
to the Q-SMART control panel terminal
(refer to figures 6,
Check connection of probes S MAX to
o
the Q-SMART control panel terminal
(refer to figures 6,
Description
A37
Minimum Level Alarm of the
water intake tank
Troubleshooting:
Only for lifting application (c02=1)
The level of water has reached the float switch G
MIN or probe S MIN. LEDs (4), (6) on.
All pumps are stopped. The alarm is excluded in
manual mode.
Causes/solutions
The level has reached the position of float
switch G MIN or probe S MIN if used. Restore
the water level.
If the alarm appears but the level has not
reached float switch G MIN or probe S MIN:
Float switch G MIN is damaged and
o
must be replaced.
Probe S MIN is damaged and must be
o
replaced.
The cable of the float switch G MIN is
o
faulty or worn, replace it.
The cable of the probe is faulty or worn,
o
replace it.
Check proper connection of the float
o
switch G MIN to the Q-SMART control
panel terminal (refer to figures 6,
9).
Description
A39
External fault alarm
Configuration of the indication of
an external alarm connected to
digital input D IN PROG (c38=2).
Troubleshooting:
7
and 9).
7
and 9).
Reset
Auto
7
and
Reset
Auto
The Alarm is detected by an external device. The logic
is configured by the parameter r38. All pumps are
stopped and they don't run until the alarm appears.
The alarm is excluded in manual mode.
Causes/solutions
Check the condition of the external device and
replace it if damaged.
If an alarm appears but the device is in good
condition:
The cable is faulty or worn, replace it.
o
Description
A54
Minimum threshold alarm
Troubleshooting:
The level of the system does not exceed the set
value of the Minimum threshold parameter (r54).
After the delay time par t54 all pumps are stopped
and protected against dry running.
The lifting application alarm doesn't stop the
pumps, it is only an alert.
The alarm is excluded in manual mode.
Causes/solutions
No water on the intake side of the pump:
check the level.
The pump (impeller or diffuser) is damaged.
Contact the technical assistance service.
The motor doesn't run:
It is damaged and must be replaced.
o
Contact the technical assistance service.
The thermal protector inside the motor
o
is faulty or broken.
The capacitor is broken.
o
Description
A55
Max threshold alarm
Troubleshooting:
The level of the system exceeds the set value of
the Maximum threshold parameter (r55).
After the delay time par t55, all the pumps are
switched on for the sewage application (c02=0).
After the delay time par t55, all the pumps are
stopped for the lifting application (c02=1)
The alarm is excluded in manual mode.
Causes/solutions
The water has exceeded the max level: check
the level.
The pump (impeller or diffuser) is damaged.
Contact the technical assistance service.
The motor doesn't run:
It is damaged and must be replaced.
o
Contact the technical assistance service.
The thermal protector inside the motor
o
is faulty or broken.
The capacitor is broken.
o
Description
A56
The same alarm is detected 5
times in the last 30 minutes
en - Original instructions
Reset
Auto
Reset
Auto
Reset
Manual
47
Tabla de contenido
loading

Tabla de contenido