5.1.2 Fabricating a model
Adapt bands (e. g. dentaform
palatal sheath to the upper first molars. Put the selected bands on
the molars. Put 2 tomas
tomas
-pins EP. The caps may require trimming (see tomas
®
Transferring the position of the tomas
can only be guaranteed with a distortion-resistant impression tray and
a silicone or polyether impression material. Using alginate or plastic
impression trays can lead to inaccuracies. To fix the tomas
and bands securely in the impression, the transfer cap and the palatal
sheaths must be surrounded with a light bodied impression material.
Then, make the impression of the jaw. After the impression material
has hardened completely, take the impression tray out of the mouth.
It is important to observe the insertion angle of the tomas
The tomas
-transfer caps and the bands should be in the impression.
®
Check if the position is correct and adjust, if necessary. If the parts can
be repositioned accurately, the impression does not have to be repeated.
After disinfecting the impression, you can start making the model.
Before pouring the model material into the impression, put the tomas
laboratory pins EP (REF 302-029-01) into the tomas
tomas
-laboratory pins must sit tightly in the transfer caps. In order for
®
the tomas
-laboratory pins not to loosen from the tomas
®
during the impression process, it is important to fix the pins with wax.
If necessary, block out the bands with wax. Then, make the model.
After the model material has hardened, carefully remove the impression
from the working model. The bands should sit on the model. If this is
not the case, put the bands back in the correct position. Remove the
tomas
-transfer caps.
®
5.1.3 Adapting amda
5.1.3.1 Adapting the amda
First, remove both amda
To remove the telescopes, loosen the stop screws and slide the
amda
telescopes off distally. Hang the eyelets of the tomas
®
abutments EP over the heads of the tomas
The anterior arch of the amda
of the anterior palate. Position the long ends of the amda
parallel to the occlusal plane at the height of the trifurcation of the
first molars (Fig.  3). This way, the width of the amda
adjusted to the width of the palate. Bend the anterior, arched part of the
amda
palatal arch using Aderer 3-Prong pliers Maxi (REF 003-202-00).
®
18
 Snap or dentaform
®
-transfer caps (REF  302-028-00) on the
®
-pin EP and the bands correctly
®
to model
®
palatal arch
®
telescopes from the amda
®
palatal arch should be parallel to the arch
®
) with conventional
®
®
-transfer caps
®
-transfer caps. The
®
-transfer caps
®
palatal arch.
®
-laboratory pins EP.
®
®
palatal arch is
®
manual).
-pins  EP.
®
-
®
-
®
palatal arch
Tabla de contenido