12 – DELETING DATA FROM THE CONTROL UNIT MEMORY
Data in the control unit memory can be deleted partially or totally as
required. To do this, the following procedures can be used, as required:
• Deletion of a command on a transmitter already memorised
• Deletion of other data memorised on the control unit
Deleting a command
on a transmitter already memorised
The following procedure enables deletion of a single command assigned
to a transmitter key from the control unit memory.
Note – During the procedure, the red and green leds remain permanently lit.
01. Press and hold the key "P1" on the Control unit for at least 10 seconds:
the green Led illuminates first, then the red led illuminates after 5 sec-
onds and then both, to indicate that the Control unit has entered mem-
ory deletion mode (WARNING! do not release the key P1!).
02. Without releasing key P1 press the transmitter key to be deleted: if
the control unit recognises this operation, the green led emits a short
flash, after which the P1 key and transmitter key can be released.
Deleting other
data memorised on the control unit
The following procedure enables deletion of various types of memorised
data from the control unit memory, as specified in Table 4.
Note – During the procedure, the red and green leds remain permanently lit.
01. Press and hold the key "P1" on the Control unit for at least 10 sec-
onds: the green Led illuminates first, then the red led illuminates after
5 seconds and then both, to indicate that the Control unit has
entered memory deletion mode. Then release the key.
02. With reference to Table 4, select the data to be deleted and press P1
the same number of times as the number of presses specified in
brackets (the green led emits one flash each time the P1 key is
pressed).
03. 5 seconds after the key "P1" is pressed for the last time, if deletion is
successful, both leds (red and green) flash quickly (= memory delet-
ed!).
Note – Before deletion, there is a margin time of 5 seconds, in which
the user has the option to change decision and exit the procedure
without deleting data by pressing key P1 five times.
IMPORTANT! – After deletion of the "Memory of Closing and Opening
limit positions" and "TOTAL Memory", the procedure 9.1 – "memorising
the devices connected by means of "bus" cable and the leaf "Clos-
ing" and "Opening" limit positions.
• Memory of Optional Function values (= 1 press)
• Memory of "Closing" and "Opening" limit positions (= 2 presses)
• Memory of Transmitters (= 3 presses)
• TOTAL memory (= 4 presses) Note – deletes the first three mem-
ories in one process
22 – English
TABLE 4
13 – AUTOMATION TESTING AND COMMISSIONING
After completing all programming phases, including adjustments, the
automation must undergo the testing and commissioning procedures as
specified in the section "Tasks reserved for qualified technicians".
14 – INSTALLING AND CONNECTING A BUFFER BATTERY
After completing the testing and commissioning phases, it is possible to
install and connect a buffer battery mod. MB, if envisaged in the system.
For this operation refer to STEP 6.5.