Check Of Number Of Manoeuvres Performed; Manoeuvre Counter Reset; 11 7.5 Connection Of Other Devices - Nice RUN1800 Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 106

Check of number of manoeuvres performed

The number of manoeuvres performed as a percentage of the set limit can be verified by means of the "Maintenance warning" function.
Follow the indications in table 17 for this check.
Table 17: check of the number of manoeuvres performed
1.
Press and hold [Set] (approx. 3 s)
2.
Release [Set] when led L1 starts flashing
3.
Press key [s] or [t] to move the flashing LED onto the input LED L7 representing the "Maintenance
warning" parameter
4.
Press and hold [Set] during steps 5, 6 and 7
5.
Wait approx. 3 seconds, after which the LED representing the current level of the parameter
"Maintenance warning" will light up.
6.
Press and immediately release the [s] and [t] keys.
7.
The LED that corresponds to the selected level flashes. The number of flashes indicates the percentage
of manoeuvres performed (in multiples of 10%) in relation to the set limit.
For example: with the maintenance warning set on L6 being 10000, 10% is equal to 1000 manoeuvres;
if the LED flashes 4 times, this means that 40% of the manoeuvres have been reached (between 4000
and 4999 manoeuvres).
The LED will not flash if 10% of the manoeuvres has not yet been reached.
8.
Release the key [Set]

Manoeuvre counter reset

After the maintenance of the system has been performed the manoeuvre counter must be reset.
Proceed as described in table 18.
Table 18: manoeuvre counter reset
1.
Press and hold [Set] (approx. 3 s)
2.
Release [Set] when led L1 starts flashing
3.
Press key [s] or [t] to move the flashing LED onto the input LED L7 representing the
"Maintenance warning" parameter
4.
Press and hold [Set] during steps 5 and 6
5.
Wait approx. 3 seconds, after which the LED representing the current level of the parameter
"Maintenance warning" will light up.
6.
Press and hold keys [s] and [t], for at least 5 seconds and then release.
The LED that corresponds to the selected level flashes rapidly indicating that the manoeuvre
counter has been reset.
7.
Release the key [Set].
7.5) Connection of Other Devices
If the user needs to feed external devices such as a proximity reader
for transponder cards or the illumination light of the key-operated
selector switch, it is possible to tap power as shown in Figure 27.
The power supply voltage is 24Vdc -30% - +50% with a maximum
available current of 100mA.
20
-
27
24Vcc
Example
SET
3s
L1
SET
or
L7
SET
3s
and
....
n=?
SET
Example
SET
3s
L1
SET
or
L7
SET
3s
and
SET
+
Tabla de contenido
loading

Este manual también es adecuado para:

Run1800pRun2500Run2500p

Tabla de contenido