The Receiver Collar is equipped to automatically increase the level of Static Correction the longer your pet remains
in the Static Correction Zone, if the collar is set at level 2 or above.
The Receiver Indicator Light acts as a low battery indicator, fl ashing every 60 seconds when battery replacement is required.

Over Correction Protection

In the unlikely event that your cat "freezes" in the Static Correction Zone, this feature limits the static correction duration
to 30 seconds. The system locks out further static correction until the pet leaves the Static Correction Zone.

Function and Response Table

Note: Begin training with Correction Level 2 and only increase if your cat does not respond to the Static Correction.
Indicator Light
Response
1 Flash
2 Flashes
3 Flashes
4 Flashes
5 Flashes
Flashes once every
4 to 5 seconds
____________________________________________________________________________________________________

Set the Boundary Width and Test the Receiver Collar

Step
6
The Boundary Control Switch on the side of the
Fence Transmitter has three settings (6A). Setting B
is used for most properties. The following table will
indicate the setting you should use.
Amount of Wire
Up to 400 m (1300 ft)
400-730 m (1300-2400 ft)
Greater than 730 m (2400 ft)
Use the Boundary Width Control knob to set the
width of the Warning Zone and Static Correction
Zone (6B). Set the Boundary Width as wide as
possible to give your cat the widest Warning and
Static Correction Zones without reducing the
Pet Area too much. We recommend a 3.7-6 m
(12-20 ft) Boundary Width.
Note: The Boundary Width Control knob does not change the Static Correction Level.
To identify the Warning and Static Correction Zones, make sure the Receiver Collar
battery is properly installed, the Static Correction Level is set at 2 or above, and the
Test Light contacts are held to the Contact Points (6C). For best results, select a
section of straight Boundary Wire that is at least 15 m (50 ft) long. Hold the Test
Light tool contacts to the Contact Points (6C). Walk toward the Boundary Wire with
Contact Points pointing up and holding the Receiver Collar at your pet's neck level
(6D) until the Receiver Collar beeps (6E) and the Test Light Tool fl ashes.
Note: The Receiver Collar is waterproof, which can make the beep hard to hear.
If the Receiver Collar does not beep at the desired range, adjust the Boundary
Width Control knob to the desired setting. Turning the Boundary
10
Static Correction
Receiver Collar Function
Level
1
No Static Correction, Beep Only
2
Low Static Correction
3
Medium Static Correction
4
Medium-High Static Correction
5
High Static Correction
Low Battery
Setting
B
C
A
www.petsafe.net
Timid
Timid or Average
Average or High Energy
High Energy
6A
Temperament of cat
6B
5
2
8
5
2
8
6C
Tabla de contenido