Mounting
4.2
Mounting the IN40@D03.. and
IN40-D0202K safety switches
The IN40-D0303K and IN40-D0202K safety switches
are not allowed to be mounted flush.
The IN40-D0303K safety switch is not allowed to be
mounted flush; this type of mounting results in the
categorisation I2A18SP2M as per EN 60947<5-2.
The IN40-D0202K safety switch is not allowed to be
mounted flush; this type of mounting results in the
categorisation I2A30SP2M as per EN 60947<5-2.
Flush installation is allowable using IN40-D0304K
safety switch: this type of mounting results in the
classification I2A18SP2M as per EN 60947-5-2.
Pay attention to safe switch off distance and enable
zone (cf. Tab. 2, Tab. 3 and Tab. 4).
The minimum distances stated in Fig. 6, Fig. 7 and
Fig. 8 for neighbouring sensors, sensors mounted
opposite and the minimum distances to fixed parts
of the plant and walls must be observed.