General Safety Notes And Protective Measures - SICK IN4000 Standard Manual Del Operador

Ocultar thumbs Ver también para IN4000 Standard:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Operating Instructions
IN4000 Standard
© SICK AG • Industrial Safety Systems • Germany • Subject to change without notice 8010934/WQ88/2013-01-15
On safety
2.4
General safety notes and protective
measures
The IN4000 Standard safety system, which comprises
one or more safety switches of the IN4000 Standard
series and the, e.g. Flexi Classic or Flexi Soft
evaluation unit, provides a personnel protection
function. As an alternative to the evaluation unit, the
safety switches can also be connected to a safe PLC.
Incorrect installation or manipulation can result in
serious injuries.
The IN4000 Standard safety system complies with the
following safety requirements:
up to category 4/Performance Level e as per
EN ISO 13849-1 (application-dependent)
category PDF-M as per EN 60947<5-3
Note on the classification of the device in compliance
with EN 60947<5-2 or EN 60947<5-3:
The IN40-D0101K safety switch complies with the
classification I1C40SP2M or I2C40SP2M
depending on the installation.
The IN40-D0303K safety switch complies with the
classification I2A18SP2M.
The IN40-D0202K safety switch complies with the
classification I2A30SP2M.
The IN40-D0304K safety switch complies with the
classification I1A18SP2M.