Fault
Motor doesn't
rotate
Motor runs away
Motor oscillates
Error message:
brake
Error message:
output stage fault
Error message:
resolver
Error message:
motor temperature
Brake does not
grip
Servomotors AKM
08/2012
Possible cause
— Servo-amplifier not enabled
— Break in setpoint lead
— Motor phases in wrong sequence
— Brake not released
— Drive is mechanically blocked
— Motor phases in wrong sequence
— Break in the shielding of the resolver cable
— amplifier gain to high
— Short-circuit in the supply voltage lead to
the motor holding brake
— Faulty motor holding brake
— Motor cable has short-circuit or earth short
— Motor has short-circuit or earth short
— Resolver connector is not properly plugged
in
— Break in resolver cable, cable crushed or
similar
— Motor thermostat has switched
— Loose resolver connector or break in
resolver cable
— Required holding torque too high
— Brake faulty
— Motor shaft axially overloaded
Setup
Measures to remove the cause of the
fault
— Supply ENABLE signal
— Check setpoint lead
— Correct the phase sequence
— Check brake controls
— Check mechanism
— Correct the phase sequence
— Replace resolver cable
— use motor default values
— Remove the short-circuit
— Replace motor
— Replace cable
— Replace motor
— Check connector
— Check cables
— Wait until the motor has cooled
down. Then investigate why the
motor becomes so hot.
— Check connector, replace resolver
cable if necessary
— Check the dimensioning
— Replace motor
— Check the axial load, reduce it.
Replace motor, since the bearings
have been damaged
English - 51