Figure 40 : Trip History
While the dialog box is active, press the left and right keys in order to scroll
through the displayed data. The name of the trip will always be shown in
the title bar of the dialog box. Press enter when finished viewing the data to
return to the trip history screen.
MAINTENANCE FOLDER
Page 1 – Filter Status
Figure 41 : Filter Status
This page displays the status of the filters. The filter status will either be "OK"
or "Change" depending on the compressor's diagnostic readings. If a filter
reaches the "change' status, a warning will be issued and the service indicator
will light up to notify the user. Note that the compressor must be in a
"Running Loaded" state to check these maintenance items. If the compressor
is not in a running state – the status will display "Load, " unless a maintenance
indicator has been issued when the machine was running and has not yet
been reset.
The following filters are displayed:
Separator Element
Page 2 - Maintenance Configuration
Figure 42 : Maintenance Configuration
This page allows the user to set the service interval and to reset the counter
after the service has been performed. The service interval may be set to any
value between 1000 and 8000 hours, but must be set in accordance with the
factory maintenance schedule. After maintenance has been performed, the
user can reset the counter by navigating to the Reset button and pressing
the enter key. Note that after changing the Service Interval a Reset must be
performed to set the Hours Until Service to the proper value.
80448483 Rev.B
RELEASED 16/Dec/2014 10:49:53 GMT
All parameters in the general settings folder are adjustable.
Language is selectable from the following 30 selections:
The controller will display all screens in the selected language and only one
language can be selected at a time.
Each language appears in its native translation.
Temperature is selectable between
Pressure is selectable between psi, kpa, bar, kg/cm
All items are adjustable.
Time allows the current time to be set in a 24 hour format
Date allows the current month, day, and year to be set
Date Format is selectable between dd/mm/yyyy (default), mm/dd/yyyy, and
YYYY/MM/DD
Confirm New Time and Date is used to verify that changes to selections are
desired. An "x" must appear in the checkbox before any changes will take
affect.
GENERAL SETTINGS FOLDER
Page 1 – Language & Units Selection
Figure 43 : Language & Units Selection
English (default)
Bulgarian
Chinese, simplified
Croatian
Czech
Danish
Dutch
Estonian
Finish
French
German
Greek
Hungarian
Italian
Indonesian
F and
o
Page 2 – Time & Date Settings
Figure 44 : Time & Date Settings
EN
Korean
Latvian
Lithuanian
Maltese
Norwegian
Polish
Portuguese
Romanian
Russian
Slovak
Slovenian
Spanish
Swedish
Thai
Turkish
C.
o
.
2
EN-23