After Use

12. Handle the device as indicated,
and pull on the end of the neck
strap to raise the device.
Position the device in front of
your chest. The device must not
be positioned too high, or pull
down on the mouthpiece.
13. If necessary, remove corrective glasses.
14. If necessary, release the goggles from the device and from the button strap
and put them on.
15. Put the chest strap around your body and close it.
16. Tighten the chest strap.
3.3
Notes for the use of the oxygen self-rescuer
Start the escape calmly, do not rush.
Plan your escape route; choose the shortest way to safe ambient air!
Behave calmly. Short, quick breaths use more oxygen!
Always make sure that the mouthpiece is tight between your teeth and lips
and cover the mouthpiece tightly with your lips.
The air from the oxygen self-rescuer is warm and dry. This shows that the
oxygen self-rescuer is functioning correctly. A possible strange taste is
normal and harmless.
Do not damage or compress the breathing bag, otherwise vital oxygen is lost.
In case of vomiting, remove the mouthpiece from your mouth and close it
with your thumb. Do not vomit into the oxygen self-rescuer!
In order to ensure that no harmful air is inhaled from the environment, inhale
from the oxygen self-rescuer first once the mouthpiece has been reinserted.
3.4
Replacing the device
If it becomes necessary to don a new training device, proceed as follows:
1.
Tighten the chest strap of the old training device to ensure that the device is
securely attached to your body.
2.
If necessary, remove the helmet.
3.
Prepare the new training device.
a.
Pull the opener up until the tightening straps fall away.
b.
Remove the upper part of the casing and dispose of it.
c.
Grasp the yellow loop of the neck strap and use it to pull the training
device out of the casing.
CAUTION
Do not pull the device out of the casing by the breathing hose. This could
damage the device.
If the oxygen self-rescuer is pulled out of the casing by the breathing hose, it
could be damaged and be unable to supply sufficient breathing air.
d.
Hold the training device so that the breathing bag points away from
the body.
4.
Open the quick-release buckle on the neck strap of the old training device.
The training device is held to the chest by the chest strap.
5.
Continue breathing with the old device.
6.
Put the neck strap of the new training device around your neck.
7.
Inhale one last time from the old training device.
8.
Bring the mouthpiece of the new training device up to your face.
In doing so, the mouthpiece cap is removed from the mouthpiece.
The starter pin is pulled out of the training device.
9.
Remove the old mouthpiece and nose clip, let it drop and place the new
mouthpiece in the mouth immediately.
Ensure that the breathing hose does not get twisted.
The rubber piece should sit between the teeth and the lips.
10. Cover the mouthpiece tightly with your lips.
11. Put the nose clip on.
The nose must be closed tightly.
12. Exhale through the new training device.
INFO
With the oxygen self-rescuer, the oxygen from the starter flows into the
breathing bag within 1 to 2 minutes. However, the breathing bag does not fill
completely. If necessary, use your hands to help unfold the breathing bag. If the
breathing bag does not fill, breathe out powerfully two or three times to fill the
breathing bag.
13. Inhale normally from the new training device.
10
14. Release the quick-release buckle of the old device's chest strap. Drop the
old device on the floor.
15. Hold the new training device by the bottom and pull on the end of the neck
strap to raise the training device.
Position the training device in front of your chest. The device must not be
positioned too high, or pull down on the mouthpiece.
16. If necessary, release the goggles from the device and from the button strap
and put them on.
17. Put the chest strap around your body and close it.
18. Tighten the chest strap.
19. If necessary, put the helmet on.
4
After Use
4.1
Cleaning the training device
00731209.eps
CAUTION
Do not use solvents (e.g. acetone, alcohol) or cleaning agents with abrasive
particles for cleaning and disinfecting. Only apply the methods described in this
document and only use the mentioned cleaning agents and disinfectants. Other
agents, dosages and exposure times may cause damage to the product.
Direct eye and skin contact with undiluted agents present a health hazard.
Therefore, always wear goggles and protective gloves when working with these
agents.
1.
Clean the training device with lukewarm water by adding Sekusept
Cleaner and using a soft rag (temperature: max. 30 °C; concentration,
depending on degree of contamination: 0.5 - 1 %)
2.
Thoroughly rinse under running water.
4.2
Disinfecting the training heat exchanger
1.
Push the O-ring of the training
heat exchanger onto the
breathing hose and loosen the
training heat exchanger from the
breathing hose.
2.
Prepare a disinfection bath
consisting of water and
®
Incidin
Rapid (temperature: max.
30 °C, concentration: 1.5 %)
3.
Put the training heat exchanger
into the disinfection bath
(duration: 15 minutes).
4.
Thoroughly rinse under running
water.
4.3
Drying the training device
Allow all parts to air-dry or be dried in the drying cabinet (temperature:
max. 60 °C). Do not expose to direct sunlight.
4.4
Reassembling the training device
1.
Ensure that the hose ring and the starter line are attached to the training
heat exchanger.
2.
Assemble the training heat exchanger:
To do this, position the training heat exchanger in such a way that the gum
seal of the mouthpiece points towards the breathing bag.
Slide the breathing hose onto the tube connection of the training heat
exchanger.
Slide the O-ring from the breathing hose onto the training heat exchanger.
3.
Adjust the chest strap and the neck strap.
4.
Fold the chest strap and fix it with a rubber band.
5.
Attach the goggles to the button strap.
6.
Attach goggles below the functional part.
7.
Insert mouthpiece cap into the mouthpiece.
1)
Sekusept
is a registered trademark of Ecolab GmbH
®
2)
Incidin
is a registered trademark of Ecolab USA Inc.
®
1)
.
2)
.
®
00531213.eps