Dynapac SD1800C Instrucciones De Manejo Y Mantenimiento página 266

Tabla de contenido
KWP
SPN
FMI
1168
1
1163
0
1169
1
1011
0
1458
0
1012
1
1459
1
1013
11
1173
14
1174
14
1175
14
1176
14
1177
14
1178
14
1187
14
918
11
360
0
361
1
1239
3
1240
3
1245
3
1246
4
1243
5
1244
12
D 23.18 104
Code
Error Identification
7-7-2
Zerofuel calibration injector 5 (in firing
order); minimum value exceeded
7-7-2
Zerofuel calibration injector 6 (in firing
order); maximum value exceeded
7-7-2
Zerofuel calibration injector 6 (in firing
order); minimum value exceeded
7-7-1
EGR cooler downstream temperature;
out of range, system reaction initiated
7-7-1
Exhaust gas temperature EGR down-
stream; out of range, system reaction ini-
tiated
7-7-1
EGR cooler downstream temperature;
out of range, system reaction initiated
7-7-1
Exhaust gas temperature EGR down-
stream; out of range, system reaction ini-
tiated
7-7-1
Sensor exhaust gas temperature Ventu-
riunit (EGR); plausibility error
7-7-9
SCR Tamper detection; derating timer
below limit 1
7-7-9
SCR Tamper detection; derating timer
below limit 2
7-8-0
Urea quality; derating timer below limit 1
7-8-0
Urea qulaity; derating timer below limit 2
7-8-1
Urea tank level; derating timer below limit
1
7-8-1
Urea tank level; derating timer below limit
2
7-8-4
Bad quality of reduction agent detected
Urea-tank without heating function (heat-
ing phase)
7-3-7
Powerstage diagnosis disabled; high bat-
tery voltage
7-3-7
Powerstage diagnosis disabled; low bat-
tery voltage
7-8-8
UB6; Short circuit to battery error of actu-
ator relay 6
7-8-9
UB7; Short circuit to battery error of actu-
ator relay 7
7-9-2
Charging lamp; short circuit to battery
7-9-2
Charging lamp; short circuit to ground
7-9-2
Charging lamp; open load
7-9-2
Charging lamp; over temperature
Short Text Detail
Zerofuel calibration injector 5 (in firing order);
minimum value exceeded
Zerofuel calibration injector 6 (in firing order);
maximum value exceeded
Zerofuel calibration injector 6 (in firing order);
minimum value exceeded
Physical range check high for EGR cooler
downstream temperature
High exhaust gas temperature EGR cooler
downstream; warning threshold exceeded
Physical range check low for EGR cooler
downstream temperature
High exhaust gas temperature EGR cooler
downstream; shut off threshold exceeded
Sensor exhaust gas temperature Venturiunit
(EGR); plausibility error
SCR Tamper detection; derating timer below
limit 1
SCR Tamper detection; derating timer below
limit 2
Urea quality; derating timer below limit 1
Urea qulaity; derating timer below limit 2
Urea tank level; derating timer below limit 1
Urea tank level; derating timer below limit 2
Bad quality of reduction agent detected
Urea-tank without heating function (heating
phase)
Powerstage diagnosis disabled; high battery
voltage
Powerstage diagnosis disabled; low battery
voltage
UB6; Short circuit to battery error of actuator
relay 7
UB7; Short circuit to battery error of actuator
relay 8
Charging lamp; short circuit to battery
Charging lamp; short circuit to ground
Charging lamp; open load
Charging lamp; over temperature
Tabla de contenido
loading

Este manual también es adecuado para:

911

Tabla de contenido