KWP
SPN
FMI
1073
4
903
0
1112
3
1113
4
1082
5
1084
5
1085
5
1088
5
1110
5
1111
12
894
13
1120
3
1121
4
1118
5
1131
3
1132
4
1493
4
1129
5
1490
5
1130
12
1491
12
1039
0
1042
1
1029
0
1032
1
Code
Error Identification
6-6-8
Sensor error urea catalyst exhaust gas
temperature upstream; signal range
check low
8-8-1
Urea tank temperature too high
6-7-1
SCR Tank heating valve; short circuit to
battery
6-7-1
SCR Tank heating valve; short circuit to
ground
7-6-2
SCR main relay (secondary side): open
load
7-6-2
SCR main relay; short circuit
7-6-2
SCR main relay; short circuit
6-7-1
SCR Tank heating valve; open load
6-7-1
SCR Tank heating valve; open load
6-7-1
SCR-heater relay urea tank powerstage
output; over temperature
8-7-2
Pressure stabilisation error dosing valve
(SCR)
6-6-6
Urea pump motor; short circuit to battery
6-6-6
Urea pump motor; short circuit to ground
6-6-6
Urea pump motor; open load
6-6-7
SCR reversing valve; short circuit to bat-
tery
6-6-7
SCR reversing valve; short circuit to
ground
6-6-7
SCR reversing valve; short circuit to
ground
6-6-7
SCR reversing valve; open load
6-6-7
SCR reversing valve; open load
6-6-7
SCR reversing valve; over temperature
6-6-7
SCR reversing valve; over temperature
6-8-3
Physical range check high for exhaust
gas temperature upstream (DOC)
6-8-3
Physical range check low for exhaust
gas temperature upstream (DOC)
6-8-4
Physical range check high for exhaust
gas temperature downstream (DOC)
6-8-4
Physical range check low for exhaust
gas temperature downstream (DOC)
Short Text Detail
Sensor error urea catalyst exhaust gas temper-
ature upstream; signal range check low
Urea tank temperature too high
SCR Tank heating valve; short circuit to battery
SCR Tank heating valve; short circuit to ground
SCR main relay (secondary side): open load
SCR main relay (secondary side); Shortcut to
battery
SCR main relay (secondary side); shortcut to
ground
SCR Tank heating valve secundary side: open
load
SCR tank heating valve primary side; open
load
SCR-heater relay urea tank powerstage output;
over temperature
Pressure stabilisation error dosing valve (SCR)
Urea pump motor; short circuit to battery
Urea pump motor; short circuit to ground
Urea pump motor; open load
SCR reversing valve; short circuit to battery
SCR reversing valve; short circuit to ground
SCR reversing valve; short circuit to ground
SCR reversing valve; open load
SCR reversing valve; open load
SCR reversing valve; over temperature
SCR reversing valve; over temperature
Physical range check high for exhaust gas tem-
perature upstream (DOC)
Physical range check low for exhaust gas tem-
perature upstream (DOC)
Physical range check high for exhaust gas tem-
perature downstream (DOC)
Physical range check low for exhaust gas tem-
perature downstream (DOC)
D 23.18 91