Dynapac SD1800C Instrucciones De Manejo Y Mantenimiento página 242

Tabla de contenido
KWP
SPN
FMI
776
3
777
4
996
0
997
0
994
3
995
4
752
0
750
3
751
4
412
3
413
4
98
0
99
0
96
3
97
4
101
1
1
11
2
11
3
11
4
11
877
3
878
4
D 23.18 80
Code
Error Identification
2-2-3
Sensor error charged air pressure; signal
range check high
2-2-3
Sensor error charged air pressure; signal
range check low
2-3-3
Charged air cooler temperature; system
reaction initiated
2-3-3
Charged air cooler temperature; system
reaction initiated
1-2-8
Sensor error charged air temperature;
signal range check high
1-2-8
Sensor error charged air temperature;
signal range check low
1-3-6
Air filter differential pressure; system
reaction initiated
1-3-6
Sensor error airfilter differential pressure;
short circuit to battery
1-3-6
Sensor error airfilter differential pressure;
short circuit to ground
2-9-2
Sensor error ambient air pressure; signal
range check high
2-9-2
Sensor error ambient air pressure; signal
range check low
2-3-2
Coolant temperature; system reaction
initiated
2-3-2
Coolant temperature; system reaction
initiated
2-2-5
Sensor error coolant temperature; signal
range check high
2-2-5
Sensor error coolant temperature; signal
range check low
2-3-5
Coolant level too low
2-2-6
Air flow sensor; sensor error
2-2-6
Air flow sensor; sensor error
2-2-6
Air flow sensor; sensor error
2-2-6
Air flow sensor; sensor error
1-4-7
Sesnor error rail pressure; signal range
check high
1-4-7
Sensor error rail pressure; signal range
check low
Short Text Detail
Sensor error charged air pressure; signal range
check high
Sensor error charged air pressure; signal range
check low
High charged air cooler temperature; warning
threshold exceeded
High charged air cooler temperature; shut off
threshold exceeded
Sensor error charged air temperature; signal
range check high
Sensor error charged air temperature; signal
range check low
High air filter differential pressure; warning
threshold exceeded
Sensor error airfilter differential pressure; short
circuit to battery
Sensor error airfilter differential pressure; short
circuit to ground
Sensor error ambient air pressure; signal range
check high
Sensor error ambient air pressure; signal range
check low
High coolant temperature; warning threshold
exceeded
High coolant temperature; shut off threshold
exceeded
Sensor error coolant temperature; signal range
check high
Sensor error coolant temperature; signal range
check low
Coolant level too low
Air flow sensor load correction factor exceeding
the maximum drift limit; plausibility error
Air flow sensor load correction factor exceeding
drift limit; plausibility error
Air flow sensor low idle correction factor
exceeding the maximum drift limit
Air flow sensor load correction factor exceeding
the maximum drift limit
Sesnor error rail pressure; signal range check
high
Sensor error rail pressure; signal range check
low
Tabla de contenido
loading

Este manual también es adecuado para:

911

Tabla de contenido