KWP
SPN
FMI
1447
4
1444
5
1445
12
1494
0
1524
0
1495
1
1525
1
1523
2
1527
2
1496
11
1526
12
385
3
386
4
383
5
384
12
1337
4
1338
4
1339
4
1340
4
1135
0
1136
1
1138
3
Code
Error Identification
Flush valve burner (EPV DPF-System);
short circuit to ground
Flush valve burner (EPV DPF-System);
open load
Flush valve burner (EPV DPF-System);
powerstage over temperature
Physical range check high for EGR mass
flow
Physical range check high for EGR
exhaust gas mass flow
Physical range check low for EGR mass
flow
Physical range check low for EGR
exhaust gas mass flow
Exhaust gas recirculation AGS sensor;
plausibility error
AGS sensor temperature exhaust gas
mass flow; plausibility error
Exhaust gas recirculation; EGR mass
flow; shut off demand
Exhaust gas recirculation; AGS sensor
has "burn off" not performed
4-1-4
Actuator EGR Valve; short circuit to bat-
tery
4-1-4
Actuator EGR Valve; short circuit to
ground
4-1-5
Actuator EGR Valve; open load
4-1-5
Actuator EGR Valve; powerstage over
temperature
Injector diagnostics; timeout error of
short circuit to ground measurement cyl.
Bank 0
Injector diagnostics; timeout error of
short circuit to ground measurement cyl.
Bank 1
Injector diagnostics; short circuit Bank 0,
Bank 1
Injector diagnostics; short circuit Bank 0,
Bank 1
6-6-9
AdBlue-Tank temperature: maximum
exceeded
6-6-9
DEF-Tank temperature: below minimum
6-6-9
Sensor error urea tank temperature;
short circuit to battery
Short Text Detail
Flush valve burner (EPV DPF-System); short
circuit to ground
Flush valve burner (EPV DPF-System); open
load
Flush valve burner (EPV DPF-System); power-
stage over temperature
Physical range check high for EGR mass flow
Physical range check high for EGR exhaust
gas mass flow
Physical range check low for EGR mass flow
Physical range check low for EGR exhaust gas
mass flow
Exhaust gas recirculation AGS sensor; plausi-
bility error
AGS sensor temperature exhaust gas mass
flow; plausibility error
Exhaust gas recirculation; EGR mass flow;
shut off demand
Exhaust gas recirculation; AGS sensor has
"burn off" not performed
Actuator EGR Valve; short circuit to battery
Actuator EGR Valve; short circuit to ground
Actuator EGR Valve; open load
Actuator EGR Valve; powerstage over temper-
ature
Injector diagnostics; timeout error of short cir-
cuit to ground measurement cyl. Bank 0
Injector diagnostics; timeout error of short cir-
cuit to ground measurement cyl. Bank 1
Injector diagnostics; short circuit to ground
monitoring Test in Cyl. Bank 0
Injector diagnostics; short circuit to ground
monitoring Test in Cyl. Bank 1
AdBlue-Tank temperature: maximum
exceeded
DEF-Tank temperature: below minimum
Sensor error urea tank temperature; short cir-
cuit to battery
D 23.18 87