KWP
SPN
FMI
450
5
455
5
451
12
456
12
946
13
947
13
121
2
1398
0
1399
1
1400
3
1401
4
849
3
850
4
1193
0
1460
0
1462
0
1194
1
1461
1
1463
1
1067
3
1068
4
Code
Error Identification
2-2-8
Fan control; open load
2-2-8
Fan control; open load
2-2-8
Fan control; internal error
2-2-8
Fan control; internal error
2-8-2
Sensor supply voltage monitor 1 error
(ECU)
2-8-2
Sensor supply voltage monitor 2 error
(ECU)
3-4-1
Engine shut off demand ignored
6-8-1
Physikal range check high for ECU tem-
perature
6-8-1
Physikal range check low for ECU tem-
perature
6-8-1
Sensor error ECU temperature; signal
range check high
6-8-1
Sensor error ECU temperature; signal
range check low
6-8-0
Sensor error pressure sensor upstream
turbine; signal range check high
6-8-0
Sensor error pressure sensor down-
stream turbine; signal range check high
Exhaust gas temperature upstream tur-
bine; out of range, system reaction initi-
ated
8-1-4
Exhaust gas temperature turbine
upstream; out of range, system reaction
initiated
5-5-6
Exhaust gas temperature turbine
upstream; out of range, system reaction
initiated
Exhaust gas temperature upstream tur-
bine; out of range, system reaction initi-
ated
8-1-4
Exhaust gas temperature turbine
upstream; out of range, system reaction
initiated
5-5-6
Exhaust gas temperature turbine
upstream; out of range, system reaction
initiated
5-5-6
Sensor error exhaust gas temperature
upstream turbine; signal range check
high
5-5-6
Sensor error exhaust gas temperature
upstream turbine; signal range check low
Short Text Detail
Digital fan control; open load
Fan actuator (PWM output); open load
Digital fan control; powerstage over tempera-
ture
Fan actuator (PWM output); powerstage over
temperature
Sensor supply voltage monitor 1 error (ECU)
Sensor supply voltage monitor 2 error (ECU)
Engine shut off demand ignored
Physikal range check high for ECU tempera-
ture
Physikal range check low for ECU temperature
Sensor error ECU temperature; signal range
check high
Sensor error ECU temperature; signal range
check low
Sensor error pressure sensor upstream tur-
bine; signal range check high
Sensor error pressure sensor downstream tur-
bine; signal range check high
Physical range check high for exhaust gas tem-
perature upstream turbine
Turbocharger Wastegate CAN feedback; warn-
ing threshold exceeded
Exhaust gas temperature upstream turbine;
warning threshold exceeded
Physical range check low for exhaust gas tem-
perature upstream turbine
Turbocharger Wastegate CAN feedback; shut
off threshold exceeded
Exhaust gas temperature upstream turbine;
shut off threshold exceeded
Sensor error exhaust gas temperature
upstream turbine; signal range check high
Sensor error exhaust gas temperature
upstream turbine; signal range check low
D 23.18 85