Dynapac SD1800C Instrucciones De Manejo Y Mantenimiento página 252

Tabla de contenido
KWP
SPN
FMI
1124
0
1123
1
1125
1
1127
3
1128
4
1104
3
1105
4
1086
5
1102
5
1096
3
1097
4
1083
5
1094
5
893
11
1092
3
1093
4
1081
5
1090
5
892
11
1069
0
1070
1
1072
3
D 23.18 90
Code
Error Identification
6-6-5
Urea pump pressure; out of range
6-6-5
Urea pump pressure; out of range
6-6-5
Urea pump pressure; out of range
6-6-5
Sensor error urea pump pressure; signal
range check high
6-6-5
Sensor error urea pump pressure; signal
range check low
6-7-5
SCR-heater urea supplyline; short circuit
to battery
6-7-5
SCR-heater urea supplyline; short circuit
to ground
6-7-5
SCR heater relay urea supplyline; open
load
6-7-5
SCR heater relay urea supplyline; open
load
6-7-3
SCR heater urea pressureline; short cir-
cuit to battery
6-7-3
SCR heater urea pressureline; short cir-
cuit to ground
6-7-3
SCR heater relay urea pressureline;
open load
6-7-3
SCR heater relay urea pressureline;
open load
8-7-1
General pressure check error (SCR)
6-7-4
SCR heater urea returnline; short circuit
to battery
6-7-4
SCR heater urea returnline; short circuit
to ground
6-7-4
SCR heater relay urea returnline; open
load
6-7-4
SCR heater relay urea returnline; open
load
8-7-0
Sensor backflow line pressure (SCR);
plausibility error
6-6-8
Physical range check high for urea cata-
lyst upstream temperature
6-6-8
Physical range low for urea catalyst
upstream temperature
6-6-8
Sensor error urea catalyst exhaust gas
temperature upstream; signal range
check high
Short Text Detail
Urea pump pressure sensor; high signal not
plusible
Physical range check low for Urea Pump Pres-
sure
Urea pump pressure sensor; low signal not
plausible
Sensor error urea pump pressure; signal range
check high
Sensor error urea pump pressure; signal range
check low
SCR-heater urea supplyline; short circuit to
battery
SCR-heater urea supplyline; short circuit to
ground
SCR heater relay urea supplyline secondary
side; open load
SCR heater relay urea supplyline primary side;
open load
SCR heater urea pressureline; short circuit to
battery
SCR heater urea pressureline; short circuit to
ground
SCR heater relay urea pressureline secondary
side; open load
SCR heater relay urea pressureline primary
side; open load
General pressure check error (SCR)
SCR heater urea returnline; short circuit to bat-
tery
SCR heater urea returnline; short circuit to
ground
SCR heater relay urea returnline sekondary
side; open load
SCR heater relay urea returnline primary side;
open load
Sensor backflow line pressure (SCR); plausibil-
ity error
Physical range check high for urea catalyst
upstream temperature
Physical range low for urea catalyst upstream
temperature
Sensor error urea catalyst exhaust gas temper-
ature upstream; signal range check high
Tabla de contenido
loading

Este manual también es adecuado para:

911