Dynapac SD1800C Instrucciones De Manejo Y Mantenimiento página 219

Tabla de contenido
KWP
SPN
FMI
628
523612
12
637
523612
12
648
523008
1
649
523008
2
732
100
3
733
100
4
734
100
0
735
100
0
736
100
1
737
100
1
738
175
2
739
175
2
740
175
0
741
175
1
743
175
3
744
175
4
745
175
0
746
175
0
747
1237
2
750
107
3
751
107
4
752
107
0
753
523919
2
Code
Error Identification
5-5-5
ECU reported internal software error
5-5-5
ECU reported internal software error
4-2-4
Manipulation control was triggered
4-2-4
Timeout error in Manipulation control
2-2-4
Sensor error oil pressure; signal range
check high
2-2-4
Sensor error oil pressure sensor; signal
range check low
2-3-1
High oil pressure; system reaction initi-
ated
2-3-1
High oil pressure; system reaction initi-
ated
2-3-1
Low oil pressure; system reaction initi-
ated
2-3-1
Low oil pressure; system reaction initi-
ated
1-4-4
Oil temperature; plausibility error
1-4-4
Oil temperature; plausibility error
1-4-4
Oil temperature; out of range, system
reaction initiated
1-4-4
Physical range check low for oil tempera-
ture
1-4-4
Sensor error oil temperature; signal
range check high
1-4-4
Sensor error oil temperature; signal
range check low
1-4-4
Oil temperature; out of range, system
reaction initiated
1-4-4
Oil temperature; out of range, system
reaction initiated
1-4-5
Override switch; plausibility error
1-3-6
Sensor error airfilter differential pressure;
short circuit to battery
1-3-6
Sensor error airfilter differential pressure;
short circuit to ground
1-3-6
Air filter differential pressure; system
reaction initiated
6-9-4
Sensor airpump pressure; plausibility
error
Short Text Detail
Internal ECU monitoring detection reported
error
Internal ECU monitoring detection reported
error
Manipulation control was triggered
Timeout error in Manipulation control
Sensor error oil pressure; signal range check
high
Sensor error oil pressure sensor; signal range
check low
High oil pressure; warning threshold exceeded
High oil pressure; shut off threshold exceeded
Low oil pressure; warning threshold exceeded
Low oil pressure; shut off threshold exceeded
Sensor oil temperature; plausibility error
Sensor oil temperature; plausibility error oil
temperature too high
Physical range check high for oil temperature
Physical range check low for oil temperature
Sensor error oil temperature; signal range
check high
Sensor error oil temperature; signal range
check low
High oil temperature; warning threshold
exceeded
High oil temperature; shut off threshold
exceeded
Override switch; plausibility error
Sensor error airfilter differential pressure; short
circuit to battery
Sensor error airfilter differential pressure; short
circuit to ground
High air filter differential pressure; warning
threshold exceeded
Sensor airpump pressure; plausibility error
D 23.18 57
Tabla de contenido
loading

Este manual también es adecuado para:

911

Tabla de contenido