Dynapac SD1800C Instrucciones De Manejo Y Mantenimiento página 248

Tabla de contenido
KWP
SPN
FMI
1066
11
1414
2
1415
7
1411
11
1412
11
1416
11
1417
11
1418
11
1413
13
85
14
82
14
86
14
747
2
610
12
604
12
605
12
606
12
607
12
608
12
609
12
460
0
461
1
1074
14
1446
3
D 23.18 86
Code
Error Identification
5-5-6
Sensor exhaust gas temperature
upstream turbine; plausibility error
8-1-4
Wastegate; status message from ECU
missing
8-1-4
Wastegate actuator; blocked
8-1-4
Turbo charger wastegate actuator; inter-
nal error
8-1-4
Turbo charger wastegate actuator; inter-
nal error
8-1-4
Turbo charger wastegate actuator; inter-
nal error
8-1-4
Turbo charger wastegate actuator; inter-
nal error
8-1-4
Turbo charger wastegate actuator; inter-
nal error
8-1-4
Wastegate actuator calibration deviation
too large, recalibration required
2-7-1
CAN-Bus 1 "BusOff-Status"
2-7-1
CAN Bus error passive; warning CAN C
2-7-1
CAN-Bus 2 "BusOff-Status"
1-4-5
Override switch; plausibility error
2-4-1
Too many recognized misfires in more
than one cylinder
2-4-1
Too many recognized misfires in cylinder
1 (in firing order)
2-4-1
Too many recognized misfires in cylinder
2 (in firing order)
2-4-1
Too many recognized misfires in cylinder
3 (in firing order)
2-4-1
Too many recognized misfires in cylinder
4 (in firing order)
2-4-1
Too many recognized misfires in cylinder
5 (in firing order)
2-4-1
Too many recognized misfires in cylinder
6 (in firing order)
2-2-8
Sensor error fan speed; signal range
check high
2-2-8
Sensor error fan speed; signal range
check low
6-7-0
Urea tank level; warning threshold
exceeded
Flush valve burner (EPV DPF-System);
short circuit to battery
Short Text Detail
Sensor exhaust gas temperature upstream tur-
bine; plausibility error
Wastegate; status message from ECU missing
Wastegate actuator; blocked
Wastegate actuator; internal error
Wastegate actuator; EOL calibration not per-
formed correctly
Wastegate actuator; over temperature (>
145°C)
Wastegate actuator; over temperature (>
135°C)
Wastegate actuator; operating voltage error
Wastegate actuator calibration deviation too
large, recalibration required
CAN-Bus 1 "BusOff-Status"
CAN Bus error passive; warning CAN C
CAN-Bus 2 "BusOff-Status"
Override switch; plausibility error
Too many recognized misfires in more than
one cylinder
Too many recognized misfires in cylinder 1 (in
firing order)
Too many recognized misfires in cylinder 2 (in
firing order)
Too many recognized misfires in cylinder 3 (in
firing order)
Too many recognized misfires in cylinder 4 (in
firing order)
Too many recognized misfires in cylinder 5 (in
firing order)
Too many recognized misfires in cylinder 6 (in
firing order)
Sensor error fan speed; signal range check
high
Sensor error fan speed; signal range check
low
Urea tank level; warning threshold exceeded
Flush valve burner (EPV DPF-System); short
circuit to battery
Tabla de contenido
loading

Este manual también es adecuado para:

911

Tabla de contenido