Type identification plate
Hilti= trademark of the Hilti Corporation, Schaan, LI
DANGER
LASER RADIATION - AVOID DIRECT
EN 60825-1:2008
EYE EXPOSURE
This Laser Product
complies with 21CFR
520-550nm < 5mW max.
1040 as applicable
CLASS IIIa LASER PRODUCT
Power: 6.0V=nom./250 mA
Item No.: 419291
Date .:
PP 25
2. Description
2.1 Use of the product as directed
The tool is designed to be used for determining, trans-
ferring or checking alignment in the horizontal and
inclined planes, e.g.: transferring heights and in pipe
laying work. Hilti supplies various accessories which
allow the tool to be used with maximum efficiency.
2.2 PP 10/25 pipe laser
The PP 10/25 is a pipe laser featuring a visible laser
beam (spot) that can be used for alignment in the
horizontal or inclined planes.
2.3 PPA 20 remote control unit
The PPA 20 is used to switch the PP 10/25 pipe laser
on and off, to activate horizontal alignment and to
select the laser beam mode remotely.
2.4 Features
A single person working with the tool can set out any
desired inclination (within the -15% to +40% range)
with great accuracy. The tool levels itself automatically
when set up within ±10% of the horizontal plane.
2.5 Automatic cut-out
The laser beam and the LED on the control panel blink
if the tool is set up outside its self-leveling range. The
direction in which the tool requires to be tilted is also
shown in the display.
Printed: 07.07.2013 | Doc-Nr: PUB / 5070160 / 000 / 00
PP 25 02
Made in Japan
3R
Location of identification data on the tool
The type designation and serial number can be found
on the type identification plate on the tool. Make a
note of this data in your operating instructions and
always refer to it when making an enquiry to your
Hilti representative or service department.
Type:
Generation: 01
Serial no.:
2.6 PPA 82 battery
Battery performance drops at low temperatures.
DANGER
Batteries should be stored at room temperature.
DANGER
Never store the battery where it is exposed to the
heat of the sun, on a radiator or behind glass, e.g.
at a window.
2.7 Automatic charging cut-out
The charging operation is stopped automatically to
protect the battery when the temperature exceeds the
specified charging temperature range.
NOTE
Charge the battery every 3 to 4 months. Store the
battery at a maximum temperature of 30°C (86°F).
Allowing the battery to become fully discharged may
have a negative effect on its future performance.
Charging may take less than 9 hours if the battery
was not previously fully discharged.
2.8 Use of various power sources
Three different power sources may be used: the
standard PPA 82 battery supplied or the PPA 83
battery holder or PPA 84 external 12V cable which
are available as accessories.
en
19