Factory setting /

EN
2
F1
F2
F3
F4
* Factory setting
** Programming example
Programming is carried out in four steps, which are
briefly summarised here (graphical presentation see
pages 27 and 28).
1.
Start manual programming
Disconnect the power supply — wait at least 20 s
— and reconnect the power supply.
When the electronics are booting, the LED in the
sensor field flashes red/yellow.
Do not put your hands into the sensor area du-
ring this phase!
Afterwards the LED is red for max. 7 s. During this
red phase, cover the sensor area under the LED
and keep it covered. Programming mode is started.
2.
Select function (F1 - F4)
The functions are now indicated one at a time by
the flashing yellow LED (see table).
To select a function, uncover the sensor area when
the corresponding code is flashing.

Manual programming

1
~ 10 mm
Parameter:
Range
Stagnation flush
Thermal disinfection
or
Permanent flow
Cleaning stop
Manual programming
Operating elements for programming:
1 LED (yellow / red)
2 Lower sensor area
Attention! For manual programming, always cover the
upper (1) and lower (2) sensor area at a distance of
approx. 10 mm!
The following table provides an overview of the main
programs and the available parameters for program-
ming the fitting manually:
P1
P2
Short
Medium *
On, 24 h after last
Off *
use
On, TD 300 s
Off *
Off *
On, 60 s
In the pictures from page 27 , manual programming is
depicted step-by-step.
As an example it is shown how to set the "range" func-
tion (F1) to "long" (P3).
3.
Set parameters
The flashing red LED shows you the currently set
parameter (see table).
By covering the sensor area again you can set the
corresponding parameter. The parameters are in-
dicated one at a time by the flashing red LED (see
table).
To set a parameter, uncover the sensor area when
the corresponding code is flashing.
4.
Start operation
After leaving the sensor area, the programming
mode starts once again with a time window of
7 seconds (red LED is on continuously).
If the sensor area is not covered during these
7 seconds, the programming is completed.
2-minute time out starts. After this, the fitting is
ready to use.
P3
Long **
On, daily every 24 h
On, 120 s
---
25