Care And Maintenance; Cleaning And Drying; Hilti Calibration Service; Troubleshooting - Hilti PMP 45 Manual De Instrucciones

Ocultar thumbs Ver también para PMP 45:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
3.
Pivot the tool clockwise through exactly 90° (as seen
from above). The lower plumb beam must remain
in the center of the reference cross and the center
of the left-hand perpendicular beam must then lie
exactly on the vertical line of target plate (a).
4.
Mark the center point (d2) of the right-hand perpen-
dicular laser beam on target plate (c).
5.
Mark the position of the laser point (d3) on the target
en
plate b or on a sheet of paper as at step 7.
NOTE The horizontal distance between d1 and d3
must be no greater than 3 mm at a working distance
of 5 m.

8 Care and maintenance

8.1 Cleaning and drying

1.
Blow dust off the lenses.
2.
Do not touch the glass with the fingers.
3.
Use only a clean, soft cloth for cleaning. If necessary,
moisten the cloth slightly with pure alcohol or a little
water.
NOTE Do not use any other liquids as these may
damage the plastic components.
4.
Observe the temperature limits when storing your
equipment. This is particularly important in winter
/ summer if the equipment is kept inside a motor
vehicle (-25°C to +63°C / -13°F to 145°F).
8.2 Storage
Remove the tool from its case if it has become wet.
The tool, its carrying case and accessories should be
cleaned and dried (at maximum 40°C / 104°F). Repack
the equipment only once it is completely dry.
Check the accuracy of the equipment before it is used
after a long period of storage or transportation.
Remove the batteries from the tool before storing it for a
long period. Leaking batteries may damage the tool.

9 Troubleshooting

Fault
The tool can't be switched on.
16
6.
7.
8.3 Transport
Use the Hilti toolbox or packaging of equivalent quality
for transporting or shipping your equipment.
CAUTION
Always remove the batteries before shipping the tool.

8.4 Hilti calibration service

We recommend that the tool is checked by the Hilti cal-
ibration service at regular intervals in order to verify its
reliability in accordance with standards and legal require-
ments.
Use can be made of the Hilti calibration service at any
time, but checking at least once a year is recommended.
The calibration service provides confirmation that the
tool is in conformance, on the day it is tested, with the
specifications given in the operating instructions.
The tool will be readjusted if deviations from the man-
ufacturer's specification are found. After checking and
adjustment, a calibration sticker applied to the tool and
a calibration certificate provide written verification that
the tool operates in accordance with the manufacturer's
specification.
Calibration certificates are always required by companies
certified according to ISO 900x.
Your local Hilti Center or representative will be pleased
to provide further information.
Possible cause
The battery is exhausted.
The battery is inserted the wrong way
round (incorrect polarity).
The battery compartment is not
closed.
The tool or the on/off switch is faulty.
Pivot the tool clockwise through exactly 180° (as
seen from above). The lower plumb beam must
remain in the center of the reference cross and the
center of the right-hand perpendicular beam must
then lie exactly on the vertical line of target plate (a).
Then mark the center point (d2) of the left-hand
perpendicular laser beam on target plate (c).
NOTE The horizontal distance between d2 and d4
must be no greater than 3 mm at a working distance
of 5 m.
NOTE If d3 is to the right of d1, the sum of the
horizontal distances d1-d3 and d2-d4 must be no
greater than 3 mm at a working distance of 5m.
NOTE If d3 is to the left of d1, the difference between
the horizontal distances d1-d3 and d2-d4 must be
no greater than 3 mm at a working distance of 5m.
Remedy
Replace the battery.
Insert the battery correctly.
Close the battery compartment.
If necessary, the power tool should be
repaired by Hilti Service.
Tabla de contenido