DETAILS OF PUMPS

as 67a 7466
1
SOLENOID VALVE (USUALLY CLOSED)
2
PRESSURE GAUGE AND AIR VENT CONNECTION (1/8" G)
3
PRESSURE REGULATION SCREW
3.1
REMOVE THE NUT TO HAVE ACCESS TO THE PRESSURE ADJUSTMENT
SCREW (11 ÷ 14 BAR)
4
RETURN
4.1
RETURN WITH INNER BY-PASS DOWEL
sWinging JaCK regULaTiOn insTrUCTiOns
adjustment of the 1st stage air gate position
To increase air supply capacity, turn ring nut C1 anticlockwise;
use the counter wrench on body A of the jack to prevent
excessive loading being exerted on the eyelet of pin H. This
action lowers body A and favours the opening of air shutter F in
first stage.To reduce the flow of air turn ring nut C2 clockwise,
also in this case use the counter wrench on the body of the
jack. In this case, this makes body A move upwards and closes
air gate F.
Once the 1st stage air regulation is complete, lock the two ring
nuts C1 and C2.
adjustment of the 2nd stage air gate position
Loosen lock nut E.
To increase 2nd stage air flow, slacken screw D; in this way the
travel distance of the hydraulic piston will be lengthened. To
reduce the delivered air flow rate tighten them.
After 2nd stage air flow adjustment, tighten nut E.
To avoid damaging eyelet H, carry out all the adjustment
operations with use of wrench and counter wrench.
an 47 - 57 - 67 - 77 - 97
5
INTAKE
6
DELIVERY
7
VACUUM GAUGE CONNECTION (1/8" G)
7.1
VACUUM GAUGE CONNECTOR AND INTERNAL BY-PASS DOWEL
The pump is preset at a 12 bar pressure
A
Hydraulic jack body
B
1st stage air regulation screw
C1, C2 Ring nuts for adjusting and locking of air shutter position
in 1st stage
D
2nd stage air regulation screw
E
Locking nut
F
Air regulation gate
G
Air inlet
H
Support eyelet