Electrical System; General Instructions - ECOFOREST ecoGEO Serie Manual De Instalador

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

5. Electrical system

Before performing any operation on the electrical panel, disconnect the power supply.
DANGER!

5.1. General instructions

The locations of the main electrical panel components are shown below.
Internal auxiliary
heater power supply
Compressor driver
Inverter
DOxx Block II
Digital outputs to
relay
DOxx Block I
Digital outputs to
relay
Controller pCO OEM+
Controller expansion
module
Electrical power filter
Controller fuse
Several installation devices are controlled from the heat pump electrical panel. Some are internal and other are installed externally.
The internal components are connected to the electrical panel in the factory. Depending on the installation that the heat pump is
going to be connected to, in addition to the power supply, it may be necessary to connect various temperature probes (analogue
inputs AIxx), control signals from thermostats or other external equipment (digital inputs DIxx) on/off switching of pumps and/or
valves (digital outputs DOxx) or regulation of pumps and/or valves (analogue outputs AOxx).
The figure below shows a sample installation with the options for connecting external components to the heat pump.
Figure 1.16. Location of the components in the electrical panel.
47
Installer manual ecoGEO
DIxx
Digital inputs
AIxx
Analogue inputs
AOxx
Analogue outputs
Fbus2
ModBus
communication port
Transformer 24 Vac
Compressor contactor
Heat
pump
power
supply
Main switch
Distributor
230/400 Vac