GB
1.
Use for intended purpose
As described in these operating instructions, the riveting tool may only be used for the
purpose of setting blind rivets. Observe the safety information!
2.
Safety information
•
The riveting tool is to be used solely for the purpose of setting rivets.
•
Never overload the tool; work within the specified working capacity.
•
Do not use tool without material! The blind rivet could be flung from the device! Never
turn the tool towards yourself or towards other persons.
•
The spent mandrel container must remain mounted on the riveting tool during operation.
•
The spent mandrel container must be emptied in good time; overfilling will cause the
riveting tool to malfunction.
•
Never use the riveting tool as a hammer.
•
Regularly check the compressed air lines to ensure they are fitted correctly and airtight.
•
The riveting tool should always be disconnected from the compressed air system when
carrying out maintenance work and when the tool is not in use.
•
Always wear protective goggles when working with the riveting tool. Personal protective
equipment such as protective clothing, gloves, safety helmet, non-slip footwear, ear
protection and fall arresting device is recommended.
•
Do not exceed the permissible working pressure.
•
When putting down the riveting tool, make sure that it cannot fall.
•
Repairs must be carried out only by skilled personnel. In case of doubt, always send in
the complete (not disassembled) riveting tool to the supplier or to GESIPA
•
Dispose of the used hydraulic oil in accordance with valid environmental protection regulations.
3.
Technical data
Tool type
Weight (kg)
Operating pressure (bar)
Hose connection (Ø mm) ¼"
Spent mandrel container capacity
Air consumption (Nl/rivet)
Compressed air quality (filtered)
Setting force (N) at 5 bar
Stroke (mm)
16
PH 2000 / PH 2000-BT
2.1
8
6
approx. 100 -200 (depending on size)
2.8 - 3.6 litres per rivet (0.6 l compressed air)
10,000 N
22
.
®